The DOI matches its Crossref record.
Rapid Detection of Picloram in Agricultural Field Samples Using a Disposable Immunomembrane-Based Electrochemical Sensor
Abstract
Picloram, a widely used chlorinated herbicide, is quite persistent and mobile in soil and water with adverse health and environmental effects. It is essential to establish a rapid and sensitive method for accurate detection of trace picloram in agricultural samples. We employed a disposable, nontoxic, and conductive chitosan/gold nanoparticles composite membrane on electrochemical sensor for the sensitive detection of picloram in several agricultural field samples. A self-synthesized picloram antibody was encapsulated in the immunomembrane to form an immunoconjugate by a competitive immunoreaction in sample solution, followed by the immobilization of horseradish peroxidase (HRP)-labeled secondary antibody. The immunomembrane possessed good reproducibility for fabrication in batch, providing a congenial microenvironment for the immune molecules. The diffused colloidal Au nanoparticles shuttled the electron transfer between the immobilized HRP and the electrode surface. To demonstrate the suitability of the immunosensor for on-site detection, rice, lettuce, and paddy field water were spiked with picloram and assayed without preconcentration. Under optimal conditions, picloram could be detected in the range from 0.005 to 10 microg/mL with the correlation coefficient of 0.9937, and the detection limit is 5 ng/ mL. The proposed immunosensor exhibited good precision, sensitivity, selectivity, and storage stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Nanomaterials for Sensing and Destroying Pesticides
Aragay, G., Pino, F., & Merkoçi, A. (2012) · Chemical Reviews · doi:10.1021/cr300020c · Cited by 573
Ren, X., Zeng, G., Tang, L., Wang, J., Wan, J., Liu, Y., Yu, J., Yi, H., Ye, S., & Deng, R. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.08.089 · Cited by 566
Self-citationLiang, J., Feng, C., Zeng, G., Gao, X., Zhong, M., Li, X., Li, X., He, X., & Fang, Y. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2017.03.057 · Cited by 565
Self-citationYang, Y., Zhang, C., Lai, C., Zeng, G., Huang, D., Cheng, M., Wang, J., Chen, F., Zhou, C., & Xiong, W. (2018) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2018.03.004 · Cited by 544
Self-citation
Metadata
- Authors
- Tang, L., Zeng, G.-M., Shen, G.-L., Li, Y.-P., Zhang, Y., & Huang, D.-L.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-01-18
- Volume
- 42
- Issue
- 4
- Pages
- 1207-1212
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2095214110
- Cited by
- 243
- References
- 0
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid Detection of Picloram in Agricultural Field Samples Using a Disposable Immunomembrane-Based Electrochemical Sensor. https://app.cochat.ai/papers/10.1021/es7024593
- The paper
- Tang, L., Zeng, G.-M., Shen, G.-L., Li, Y.-P., Zhang, Y., & Huang, D.-L. (2008). Rapid Detection of Picloram in Agricultural Field Samples Using a Disposable Immunomembrane-Based Electrochemical Sensor. Environmental Science & Technology. https://doi.org/10.1021/es7024593
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.