Immobilization of Selenite on Fe3O4 and Fe/Fe3C Ultrasmall Particles
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The sorption of selenite ions onto Fe3O4 and Fe/Fe3C nanoparticles (NPs) was studied in aqueous solutions under anoxic conditions using gamma spectrometry and X-ray absorption spectrometry (XAS) techniques. This is the first study related to the remedial applications of Fe/Fe3C NPs. FesO4 NPs have been prepared by conventional coprecipitation of Fe(II) and Fe(III) in basic solutions. Stable Fe/Fe3C NPs have been prepared by Fe(CO)5 sonicating in diphenylmethane solutions and subsequently annealing the as-prepared product. Kinetic study demonstrated that Se(IV) sorption is extremely rapid: the equilibrium is reached in approximately 10 and 30 min for Fe3O4 and Fe/Fe3C NPs, respectively, at pH = 4.9-5.1 in solutions of 0.1 M NaCl. The distribution coefficients are also very high for both kinds of NPs (Kd > 3000). Increasing the pH to 10.3 or adsorption of organic ligands, like L-lysine or dodecanoate, at the surface of NPs causes the decrease in Kd values. However, even in these cases Kd values exceed 150. Magnetic NPs loaded with selenium can be easily and completely removed from solution with a 0.4 T permanent magnet. XAS study revealed the absence of Se(IV) reduction during the sorption onto Fe3O4 NPs in the pH range of 4.8-8.0. By contrast, the removal of Se(IV) with Fe/Fe3C NPs in anaerobic conditions occurs via Se(IV) reduction to Se(-II) and subsequent formation of iron selenide at the particle surface. Thus, the Fe/Fe3C NPs are superior to Fe3O4 NPs due to their ability to immobilize rapidly and irreversibly Se(IV) via reductive mechanism. Presumably these particles could be also effective for the removal of other contaminants such as hexavalent chromium, actinides, technetium, and toxic organic compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selenate and Selenite Sorption on Iron Oxides An Infrared and Electrophoretic Study
Su, C., & Suarez, D. L. (2000) · Soil Science Society of America Journal · doi:10.2136/sssaj2000.641101x · Cited by 261
Cited by
A novel magnetic biochar efficiently sorbs organic pollutants and phosphate
Chen, B., Chen, Z., & Lv, S. (2011) · Bioresource Technology · doi:10.1016/j.biortech.2010.08.067 · Cited by 1,026
Selenium environmental cycling and bioavailability: A structural chemist point of view
Fernández-Martínez, A., & Charlet, L. (2009) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-009-9145-3 · Cited by 487
Fan, X., Peng, Z., Ye, R., Zhou, H., & Guo, X. (2015) · ACS Nano · doi:10.1021/acsnano.5b02420 · Cited by 476
Wang, Y., Sun, H., Duan, X., Ang, H. M., Tadé, M. O., & Wang, S. (2015) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2015.02.016 · Cited by 283
Awual, M. R., Yaita, T., Suzuki, S., & Shiwaku, H. (2015) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.02.066 · Cited by 279
Metadata
- Authors
- López de Arroyabe Loyo, R., Nikitenko, S. I., Scheinost, A. C., & Simonoff, M.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-02-20
- Volume
- 42
- Issue
- 7
- Pages
- 2451-2456
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2437315911
- Cited by
- 120
- References
- 1
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.