Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 246

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Oxidation of Diclofenac with Ozone in Aqueous Solution

Sein, Myint Myint, Zedda, Marco, Tuerk, Jochen, Schmidt, Torsten C., Golloch, Alfred, von Sonntag, Clemens·2008·Environmental Science & Technology

Abstract

Ozonation of diclofenac in aqueous solution in the presence and absence of an *OH scavenger, tertiary butanol (t-BuOH), was studied, and the most important reaction intermediates and products were identified. The second-order O3 rate constantwas determined by competition with buten-3-ol and was found to be 6.8 x 10(5) M(-1) s(-1) at 20 degrees C. From this high rate constant, it has been concluded that O3 must initially add on the amino nitrogen. Decomposition of the adduct results in the formation of O3*- (--> *OH) and aminyl radical precursors. A free *OH yield of 30% was estimated based on the HCHO yields generated upon reaction of *OH with 0.01 M t-BuOH. Almost all diclofenac reacted when the molar ratio of O3/diclofenac was approximately 5:1 in the presence of t-BuOH and approximately 8:1 in its absence. As primary reaction products (maximum yield), diclofenac-2,5-iminoquinone (32%), 5-hydroxydiclofenac (7%), and 2,6-dichloroaniline (19%) were detected with respect to reacted diclofenac in the presence of t-BuOH. These primary products degraded into secondary ones when the O3 dose was increased. In the *OH-mediated reaction (absence of t-BuOH) small yields of 5-hydroxydiclofenac (4.5%), diclofenac-2,5-iminoquinone (2.7%), and 2,6-dichloroaniline (6%) resulted. Practically all Cl- (95%) was released in the absence of t-BuOH but only about 45% in the presence of t-BuOH at an O3/diclofenac molar ratio of 10: 1. Based on the reaction products, mechanisms that may account for the high O3 consumption during ozonation of diclofenac are suggested. For technical applications, adequate supply of O3 is needed not only to eliminate diclofenac, but also for the degradation of its potentially toxic products like diclofenac-2,5-iminoquinone and 5-hydroxydiclofenac.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es8008612

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Sein, M. M., Zedda, M., Tuerk, J., Schmidt, T. C., Golloch, A., & von Sonntag, C.
Venue
Environmental Science & Technology
Published
2008-07-29
Volume
42
Issue
17
Pages
6656-6662
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2054958810
Cited by
246
References
1
FWCI
10.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.