Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Relating Colloidal Stability of Fullerene (C60) Nanoparticles to Nanoparticle Charge and Electrokinetic Properties

Chen, Kai Loon, Elimelech, Menachem · 2009 · Environmental Science & Technology

Abstract

The stability and aggregation kinetics of two different suspensions of fullerene (C60) nanoparticles and their relation to nanoparticle charge (electrokinetic) properties were investigated. The two synthesis methods employed--a solvent exchange method involving sonication of fullerene initially dissolved in toluene and prolonged stirring of bulk fullerene in water--produce negatively charged fullerene nanoparticles. With an increase in electrolyte (KCl) concentration, the electrophoretic mobilities of both fullerene nanoparticles became less negative, while the corresponding aggregation rates increased until maximum rates were reached at their respective critical coagulation concentrations. This behavior is consistent with the classic Derjaguin-Landau-Verwey-Overbeek (DLVO) theory for the stability of charged colloidal particles. The nanoparticles prepared by prolonged stirring of bulk fullerene in water were much more stable than those prepared by sonication in toluene, as evident from their significantly higher critical coagulation concentration (166 and 40 mM KCl, respectively). A comparison of the aggregation kinetics with predictions based on DLVO theory yielded the same Hamaker constant (8.5 x 10(-21) J) for both fullerene nanoparticles, indicating that they have the same material composition. Further investigation shows that both fullerene nanoparticles are more negatively charged and stable at higher pH conditions, suggesting that dissociation of surface functional groups contributes to surface charge for both nanoparticles. This hypothesis is further supported by oxidation which occurs on the surface of bulk fullerene that has been exposed to water over a prolonged period of time, as detected through X-ray photoelectron spectroscopy (XPS). However, since both nanoparticles remain negatively charged at pH 2, it is likely that there are other contributing factors to the surface charge of fullerene nanoparticles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es900185p

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Chen, K. L., & Elimelech, M.
Venue
Environmental Science & Technology
Published
2009-04-29
Volume
43
Issue
19
Pages
7270-7276
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2048198341
Cited by
187
References
1
FWCI
11.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.