CoChat

Branched Perfluorooctane Sulfonate Isomer Quantification and Characterization in Blood Serum Samples by HPLC/ESI-MS(/MS)

Riddell, Nicole, Arsenault, Gilles, Benskin, Jonathan P., Chittim, Brock, Martin, Jonathan W., McAlees, Alan, McCrindle, Robert · 2009 · Environmental Science & Technology
Cited by 121

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Perfluorooctane sulfonate (PFOS) is a global contaminant and is currently among the most prominent contaminants in human blood and wildlife samples. Although "total PFOS" (SigmaPFOS) analytical methods continue to be the most commonly used for quantification, recent analytical method developments have made it possible to resolve the various isomers of PFOS by HPLC-MS/MS. Characterized technical PFOS standards (i.e., containing a mixture of PFOS isomers) are now available that enable isomer specific quantification of PFOS, however the advantages of such an analysis have notyet been examined systematically. Herein, PFOS isomers have been individually quantified for the first time in real samples and the results are compared to a traditional SigmaPFOS method; the influence of analytical standards and isomer specific electrospray and MS/ MS behavior were also investigated. The two human serum standard reference materials chosen for analysis contained dramaticallydifferent PFOS isomer profiles (approximately 30-50% total branched isomers) emphasizing that isomer patterns should not be ignored and may provide useful information on exposure sources (i.e., direct exposure to PFOS vs indirect exposure from PFOS-precursors). Depending on the sample and the particular MS/MS transition chosen for SigmaPFOS analysis (i.e., 499-->80 or 499-->99), SigmaPFOS concentrations may be over- or underestimated compared to the isomer specific analysis. Differences in the extent of in-source fragmentation and MS/MS dissociation contributed to the systematic analytical bias. It was also shown that SigmaPFOS data are prone to interlaboratory variation due to various choices of PFOS standards and instrumental conditions used. In the future, for either SigmaPFOS or isomer specific PFOS analyses, we suggest that accuracy can be maximized and interlaboratory discrepancies minimized by using a common chemically pure technical PFOS standard characterized by 19F NMR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es901261v

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 121

Metadata

Authors
Riddell, N., Arsenault, G., Benskin, J. P., Chittim, B., Martin, J. W., McAlees, A., & McCrindle, R.
Venue
Environmental Science & Technology
Published
2009-09-17
Volume
43
Issue
20
Pages
7902-7908
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W1999027093
Cited by
121
References
1
FWCI
7.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.