Accelerated Solvent Extraction: An Evaluation for Screening of Soils for Selected U.S. EPA Semivolatile Organic Priority Pollutants
The DOI matches its Crossref record.
Abstract
Accelerated solvent extraction (ASE) was evaluated as a possible rapid, low solvent replacement for Soxhlet and bath sonication/shaking extraction in established soil screening methods. A spiked uncontaminated clay loam and soils contaminated with organochlorine pesticides (OCPs) and polycyclic aromatic hydrocarbons (PAHs) were extracted with 1:1 dichloromethane/acetone. Extracts were analyzed by gas chromatography with mass spectrometric detection in selective ion monitoring mode. For the spiked soil, ASE recoveries were higher than those from Soxhlet extraction for most analytes and generally close to 100% at the 4 and 20 mg/kg levels. At the 0.4 mg/kg level, background peaks caused significant interference for both techniques. This was a greater problem for ASE as the method blank gave a more crowded, complex chromatogram. For the OCP soil, ASE gave higher results than Soxhlet but lower results than bath sonication/shaking, for which a more effective solvent for OCPs was used. For the PAH soils, ASE recoveries were equivalent or superior to bath sonication/shaking, with ASE giving approximately double the total PAH content for matrices containing small stones and/or coal. ASE would be a suitable replacement for existing extraction methods; however, more work is required to reduce background interference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of ultrasound in food technology: Processing, preservation and extraction
Chemat, F., Zill-e-Huma, & Khan, M. K. (2011) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2010.11.023 · Cited by 2,533
Recent development in the treatment of oily sludge from petroleum industry: A review
Hu, G., Li, J., & Zeng, G. (2013) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2013.07.069 · Cited by 1,069
Kaufmann, B., & Christen, P. (2002) · Phytochemical Analysis · doi:10.1002/pca.631 · Cited by 831
“Most papers stress the shorter extraction times and lower solvent consumption of ASE in comparison to other conventional preparation techniques of environmental samples with the exception of SFE (Richter et al., 1995; Jensen et al., 1996; Kreisselmeier and Dürbeck, 1997; Fisher et al., 1997).”
Soxhlet extraction of solid materials: an outdated technique with a promising innovative future
Luque de Castro, M. D., & Garcı́a-Ayuso, L. E. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00233-5 · Cited by 727
Camel, V. (2001) · The Analyst · doi:10.1039/b008243k · Cited by 347
Pressurised liquid extraction of persistent organic pollutants in environmental analysis
Björklund, E., Nilsson, T., & Bøwadt, S. (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(00)00002-9 · Cited by 252
Chiaia-Hernandez, A. C., Keller, A., Wächter, D., Steinlin, C., Camenzuli, L., Hollender, J., & Krauss, M. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b02529 · Cited by 206
Wang, W., Meng, B., Lu, X., Liu, Y., & Tao, S. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.09.023 · Cited by 187
Sosa Ferrera, Z., Padrón Sanz, C., Mahugo Santana, C., & Santana Rodrı́guez, J. J. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00732-0 · Cited by 184
Ultrasound-Assisted Extraction in Food Analysis
Chemat, F., Tomao, V., & Virot, M. (2008) · Handbook of Food Analysis Instruments · doi:10.1201/9781420045673.ch5 · Cited by 138
Metadata
- Authors
- Fisher, J. A., Scarlett, M. J., & Stott, A. D.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-03-27
- Volume
- 31
- Issue
- 4
- Pages
- 1120-1127
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2087864033
- Cited by
- 125
- References
- 0
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.