The DOI matches its Crossref record.
Tracing Organic Contaminants in Groundwater: A New Methodology Using Compound-Specific Isotopic Analysis
Abstract
The low concentrations (ppm to ppb) typical of organic pollutants dissolved in groundwater have been a major factor limiting the application of stable isotope tracing techniques at contaminated field sites. In this study, pentane extraction of benzene, toluene, ethylbenzene, and the xylene isomers (BTEX) from water is shown to be an excellent means of resolving this problem and preparing low concentration samples for carbon isotope analysis using high sensitivity gas chromatograph/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Pentane extraction provides accurate, reproducible, and linear isotopic results for dissolved BTEX in water with concentrations ranging from 0.1 to 100 ppm a range typically found in contaminated field settings. It is a rapid and flexible technique for extracting the monoaromatics from water and can readily be adapted to extract other organic contaminants. Demonstration of the feasibility of this technique for sparingly soluble BTEX compounds paves the way for applications of δ 13 C analysis of dissolved contaminants in both laboratory and field scenarios. GC/C/IRMS analysis of pure phase BTEX obtained from different manufacturers shows that the δ 13 C values of these compounds are resolvably different for each producer. These results suggest that isotope analysis may be a valuable tool for identification of contaminant origin in well-constrained field situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Peters, K. E., Walters, C. C., & Moldowan, J. M. (2004) · Cambridge University Press eBooks · doi:10.1017/cbo9780511524868 · Cited by 2,089
Elsner, M., Zwank, L., Hunkeler, D., & Schwarzenbach, R. P. (2005) · Environmental Science & Technology · doi:10.1021/es0504587 · Cited by 572
Stable isotope fractionation analysis as a tool to monitor biodegradation in contaminated acquifers
Meckenstock, R. U., Morasch, B., Griebler, C., & Richnow, H. H. (2004) · Journal of Contaminant Hydrology · doi:10.1016/j.jconhyd.2004.06.003 · Cited by 438
Meckenstock, R. U., Haderlein, S. B., Schmidt, T. C., Zwank, L., Elsner, M., & Berg, M. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2350-y · Cited by 389
Forensic applications of isotope ratio mass spectrometry—A review
Benson, S., Lennard, C., Maynard, P., & Roux, C. (2006) · Forensic Science International · doi:10.1016/j.forsciint.2005.03.012 · Cited by 292
Sherwood Lollar, B., Slater, G. F., Sleep, B., Witt, M., Klecka, G. M., Harkness, M., & Spivack, J. (2001) · Environmental Science & Technology · doi:10.1021/es001227x · Cited by 272
Self-citation
Metadata
- Authors
- Dempster, H. S., Sherwood Lollar, B., & Feenstra, S.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-10-29
- Volume
- 31
- Issue
- 11
- Pages
- 3193-3197
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1997449145
- Cited by
- 171
- References
- 0
- FWCI
- 16.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.