Modeling Ozone Levels in and around Southern California Homes
The DOI matches its Crossref record.
Abstract
To investigate residential ozone (O 3 ) concentrations and their relationship to regional monitoring data, we studied 126 southern California homes between February and December 1994. Using a controlled flow sampler, 481 samples were collected over 24 h sampling periods, both inside ( n = 241) and immediately outside ( n = 240) residences. Indoor O 3 levels (13 ± 12 ppb, arithmetic mean) were almost always below observed outdoor measurements (37 ± 19 ppb). Low outdoor concentrations resulted in uniformly low indoor concentrations, but high outdoor levels resulted in a range of indoor levels. Indoor/outdoor ratios (0.37 ± 0.25) were greater during the summer pollution period. Using information collected from interviews performed before and after sampling, we explored relationships between measured indoor O 3, home operating characteristics, and ambient O 3 reported at the closest regional monitoring station. Indoor O 3 levels were largely determined by outdoor O 3 levels and the duration of time that windows were kept open. Ozone measured adjacent to study homes predicted indoor levels no better than station ambient values. These data suggest that ambient O 3 measured at regional stations, coupled with information about how homes are operated, predict in-home O 3 levels moderately well and are potentially useful for future exposure assessment purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ambient Air Pollution and Atherosclerosis in Los Angeles
Künzli, N., Jerrett, M., Mack, W. J., Beckerman, B., LaBree, L., Gilliland, F., Thomas, D., Peters, J., & Hodis, H. N. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7523 · Cited by 809
Asthma in exercising children exposed to ozone: a cohort study
McConnell, R., Berhane, K., Gilliland, F., London, S. J., Islam, T., Gauderman, W. J., Avol, E., Margolis, H. G., & Peters, J. M. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07597-9 · Cited by 796
Self-citationOzone in Indoor Environments: Concentration and Chemistry
WESCHLER, C. J. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004269.x · Cited by 758
Weschler, C. J. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9256 · Cited by 481
Associations Between Ozone and Daily Mortality: Analysis and Meta-Analysis
Ito, K., De Leon, S. F., & Lippmann, M. (2005) · Epidemiology · doi:10.1097/01.ede.0000165821.90114.7f · Cited by 384
Ozone Exposure and Mortality: An Empiric Bayes Metaregression Analysis
Levy, J. I., Chemerynski, S. M., & Sarnat, J. A. (2005) · Epidemiology · doi:10.1097/01.ede.0000165820.08301.b3 · Cited by 302
“In addition, because ozone is highly reactive in indoor environments (where people spend most of their time), ambient ozone concentrations tend to be higher than personal ozone exposures.(12,13) This makes epidemiologic findings based on central site monitors difficult to interpret.”
BackgroundLogue, J. M., McKone, T. E., Sherman, M. H., & Singer, B. C. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00683.x · Cited by 266
Ozone and daily mortality in Shanghai, China
Zhang, Y., Huang, W., London, S. J., Song, G., Chen, G., Jiang, L., Zhao, N., Chen, B., & Kan, H. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9014 · Cited by 163
Metadata
- Authors
- Avol, E. L., Navidi, W. C., & Colome, S. D.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-01-16
- Volume
- 32
- Issue
- 4
- Pages
- 463-468
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2052659969
- Cited by
- 61
- References
- 0
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.