The DOI matches its Crossref record.
Comparison among the Methods for Hydrogen Peroxide Measurements To Evaluate Advanced Oxidation Processes: Application of a Spectrophotometric Method Using Copper(II) Ion and 2,9-Dimethyl-1,10-phenanthroline
Abstract
Hydrogen peroxide (H 2 O 2 ) in the range of several tens to several hundreds of micromoles per liter is usually added to the process water in advanced oxidation processes (AOPs). In this study, a spectrophotometric method using copper(II) ion and 2,9-dimethyl-1,10-phenanthroline (DMP) for measuring H 2 O 2 concentration was compared with other methods [i.e., spectrophotometric methods using titanium oxalate and N, N -diethyl- p -phenylenediamine (DPD) and a fluorometric method using p -hydroxyphenyl acetic acid (POHPAA)]. Particular attention was paid to sensitivities and effects of coexisting substances. The most sensitive method was the fluorometric method, followed in order by DPD, DMP, and the titanium oxalate colorimetric method; their detection limits in 1-cm cells were 0.16, 0.77, 0.80, and 29 μM, respectively. Therefore, the DMP method was found to be reasonably sensitive when applied to AOPs. Also, the DMP reagent is commercially available, and the absorbance of Cu(DMP) 2 +, a reaction product of the DMP method, was not affected by reaction time. In the DMP method, copper(II)−DMP complexes react with humic acid, and colored chemicals are produced. However, the slopes of the calibration curves of H 2 O 2 containing up to 10 mg of C L - 1 from humic acid did not change significantly as compared to that in ultrapure water. The effect of chlorine on the DMP method was not observed up to at least 23 μM (0.8 mg of Cl L - 1 ) of free chlorine, although the DPD and fluorometric methods are known to be interfered by chlorine. From this study, it was concluded that the DMP method is suitable to be used in AOPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
NOGUEIRA, R., OLIVEIRA, M., & PATERLINI, W. (2005) · Talanta · doi:10.1016/j.talanta.2004.10.001 · Cited by 951
Methods for reactive oxygen species (ROS) detection in aqueous environments
Burns, J. M., Cooper, W. J., Ferry, J. L., King, D. W., DiMento, B. P., McNeill, K., Miller, C. J., Miller, W. L., Peake, B. M., Rusak, S. A., et al. (2012) · Aquatic Sciences · doi:10.1007/s00027-012-0251-x · Cited by 454
Photocatalytic Oxidation of Arsenite in TiO2 Suspension: Kinetics and Mechanisms
Lee, H., & Choi, W. (2002) · Environmental Science & Technology · doi:10.1021/es0158197 · Cited by 402
Wu, W., Huang, Z.-H., & Lim, T.-T. (2014) · Applied Catalysis A: General · doi:10.1016/j.apcata.2014.04.035 · Cited by 349
Sulfur-Doped Laser-Induced Porous Graphene Derived from Polysulfone-Class Polymers and Membranes
Singh, S. P., Li, Y., Zhang, J., Tour, J. M., & Arnusch, C. J. (2018) · ACS Nano · doi:10.1021/acsnano.7b06263 · Cited by 347
Metadata
- Authors
- Kosaka, K., Yamada, H., Matsui, S., Echigo, S., & Shishida, K.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-10-17
- Volume
- 32
- Issue
- 23
- Pages
- 3821-3824
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2043458123
- Cited by
- 251
- References
- 0
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison among the Methods for Hydrogen Peroxide Measurements To Evaluate Advanced Oxidation Processes: Application of a Spectrophotometric Method Using Copper(II) Ion and 2,9-Dimethyl-1,10-phenanthroline. https://app.cochat.ai/papers/10.1021/es9800784
- The paper
- Kosaka, K., Yamada, H., Matsui, S., Echigo, S., & Shishida, K. (1998). Comparison among the Methods for Hydrogen Peroxide Measurements To Evaluate Advanced Oxidation Processes: Application of a Spectrophotometric Method Using Copper(II) Ion and 2,9-Dimethyl-1,10-phenanthroline. Environmental Science & Technology. https://doi.org/10.1021/es9800784
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.