Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 240

The DOI matches its Crossref record.

A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples

Beyerle, Urs, Aeschbach-Hertig, Werner, Imboden, Dieter M., Baur, Heinrich, Graf, Thomas, Kipfer, Rolf · 2000 · Environmental Science & Technology

Abstract

The design, setup, and performance of a mass spectrometric system for the analysis of noble gas isotopes ( 3 He, 4 He, 20 Ne, 21 Ne, 22 Ne, 36 Ar, 40 Ar, 84 Kr, 136 Xe) and tritium ( 3 H) from water samples are described. The 3 H concentration is measured indirectly by the 3 He ingrowth from radioactive decay. After extraction, purification, and separation, the noble gases are measured in two noncommercial double-collector 90° magnetic sector mass spectrometers. We present a new approach for the analysis of the heavy noble gas isotopes that enables, in principle, simultaneous measurement of Ar, Kr, and Xe. Typical precisions of the measurements of 3 H, He, Ne, Ar, Kr, and Xe concentrations are ±2.7%, ±0.3%, ±0.9%, ±0.3%, ±0.8%, and ±1.0%, respectively. For the isotopic ratios 3 He/ 4 He, 20 Ne/ 22 Ne, and 40 Ar/ 36 Ar the typical precisions are ±0.7%, ±0.3%, and ±0.2%. These values express the reproducibility of the measurement of an internal freshwater standard and include the overall stability of the system as well as of the extraction procedure. To verify the method, the noble gas concentrations of air-saturated water samples prepared under controlled conditions are compared with noble gas solubility data. The 20 Ne/ 22 Ne and 36 Ar/ 40 Ar fractionation during solution is estimated from 70 surface water samples to be −2.0 ± 0.2‰ and −1.3 ± 0.2‰, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es990840h

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 240

Metadata

Authors
Beyerle, U., Aeschbach-Hertig, W., Imboden, D. M., Baur, H., Graf, T., & Kipfer, R.
Venue
Environmental Science & Technology
Published
2000-04-14
Volume
34
Issue
10
Pages
2042-2050
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2047299236
Cited by
240
References
0
FWCI
11.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples. https://app.cochat.ai/papers/10.1021/es990840h
The paper
Beyerle, U., Aeschbach-Hertig, W., Imboden, D. M., Baur, H., Graf, T., & Kipfer, R. (2000). A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples. Environmental Science & Technology. https://doi.org/10.1021/es990840h

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.