The DOI matches its Crossref record.
A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples
Abstract
The design, setup, and performance of a mass spectrometric system for the analysis of noble gas isotopes ( 3 He, 4 He, 20 Ne, 21 Ne, 22 Ne, 36 Ar, 40 Ar, 84 Kr, 136 Xe) and tritium ( 3 H) from water samples are described. The 3 H concentration is measured indirectly by the 3 He ingrowth from radioactive decay. After extraction, purification, and separation, the noble gases are measured in two noncommercial double-collector 90° magnetic sector mass spectrometers. We present a new approach for the analysis of the heavy noble gas isotopes that enables, in principle, simultaneous measurement of Ar, Kr, and Xe. Typical precisions of the measurements of 3 H, He, Ne, Ar, Kr, and Xe concentrations are ±2.7%, ±0.3%, ±0.9%, ±0.3%, ±0.8%, and ±1.0%, respectively. For the isotopic ratios 3 He/ 4 He, 20 Ne/ 22 Ne, and 40 Ar/ 36 Ar the typical precisions are ±0.7%, ±0.3%, and ±0.2%. These values express the reproducibility of the measurement of an internal freshwater standard and include the overall stability of the system as well as of the extraction procedure. To verify the method, the noble gas concentrations of air-saturated water samples prepared under controlled conditions are compared with noble gas solubility data. The 20 Ne/ 22 Ne and 36 Ar/ 40 Ar fractionation during solution is estimated from 70 surface water samples to be −2.0 ± 0.2‰ and −1.3 ± 0.2‰, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Arsenic Contamination of Groundwater and Drinking Water in Vietnam: A Human Health Threat
Berg, M., Tran, H. C., Nguyen, T. C., Pham, H. V., Schertenleib, R., & Giger, W. (2001) · Environmental Science & Technology · doi:10.1021/es010027y · Cited by 1,096
Noble Gases in Lakes and Ground Waters
Kipfer, R., Aeschbach-Hertig, W., Peeters, F., & Stute, M. (2002) · Reviews in Mineralogy and Geochemistry · doi:10.2138/rmg.2002.47.14 · Cited by 406
Self-citationRetardation of arsenic transport through a Pleistocene aquifer
van Geen, A., Bostick, B. C., Thi Kim Trang, P., Lan, V. M., Mai, N.-N., Manh, P. D., Viet, P. H., Radloff, K., Aziz, Z., Mey, J. L., et al. (2013) · Nature · doi:10.1038/nature12444 · Cited by 170
Self-citation
Metadata
- Authors
- Beyerle, U., Aeschbach-Hertig, W., Imboden, D. M., Baur, H., Graf, T., & Kipfer, R.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-04-14
- Volume
- 34
- Issue
- 10
- Pages
- 2042-2050
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2047299236
- Cited by
- 240
- References
- 0
- FWCI
- 11.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples. https://app.cochat.ai/papers/10.1021/es990840h
- The paper
- Beyerle, U., Aeschbach-Hertig, W., Imboden, D. M., Baur, H., Graf, T., & Kipfer, R. (2000). A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples. Environmental Science & Technology. https://doi.org/10.1021/es990840h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.