Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Mineralization of Steroidal Hormones by Biosolids in Wastewater Treatment Systems in Tennessee U.S.A.

Layton, A. C., Gregory, B. W., Seward, J. R., Schultz, T. W., Sayler, G. S.·2000·Environmental Science & Technology

Abstract

During the past several years, concern has risen over potential pollution of waterways with estrogenic compounds, including steroidal hormones from human and animal sources. One potential source of steroid hormone contamination is through the incomplete removal of these compounds in wastewater treatment systems (WTS). To address this issue, laboratory mineralization assays using 14 C-labeled estrogens and testosterone were performed with biosolids from four municipal treatment plants and one industrial system. The importance of adapted microbial populations in the removal of estrogen was shown by the dramatic differences in mineralization of 14 C-17β-estradiol by biosolids from a municipal plant compared to that from the industrial plant, 84% versus 4%, respectively. Indeed, biosolids from all of the municipal plants mineralized 70−80% of added 14 C-17β-estradiol to 14 CO 2 in 24 h. Removal of 14 C-17β-estradiol from the aqueous phase by biodegradation and/or biosorption to cell matter was greater than 90%. A recombinant yeast estrogen assay (YES assay) also confirmed that biological estrogenic activity was removed from the biosolid samples to below the detection limit (1.56 nM). 14 C-Testosterone was mineralized to 14 CO 2 in all four municipal biosolids in amounts ranging from 55% to 65%; moreover, total removal of 14 C-testosterone from the aqueous phase was 95%. First-order rate constants k were obtained for the mineralization and removal from the aqueous phase of natural and a synthetic steroid hormone in biosolids from one WTP. In these biosolids, 14 C-17β-estradiol and 14 C-testosterone were rapidly mineralized to 14 C-CO 2 ( k = 0.0042 ±0.0002 min - 1 and 0.0152 ± 0.0021 min - 1, respectively), whereas the mineralization of the synthetic estrogen 14 C-17α-ethinylestradiol was 25−75-fold less ( k = 0.0002 ± 0.0000 min - 1 ). In addition, mineralization of 14 C-ethinylestradiol did not reach completion in 24 h with only 40% mineralized to 14 C-CO 2 . Approximately 20% of the 14 C-ethinylestradiol remained in the aqueous phase and was biologically active as determined by the YES assay. Changes in temperature of approximately 15 °C had a statistically significant effect on the rate of mineralization and removal of 14 C-17β-estradiol from the aqueous phase but not for 14 C-testosterone or 14 C-17α-ethinylestradiol. These results suggest that biosolids in municipal plants in this region have the capability to remove natural steroid hormones in their influents over a range of temperatures but may be less effective at removing the synthetic estrogen 17α-ethinylestradiol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es9914487

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Layton, A. C., Gregory, B. W., Seward, J. R., Schultz, T. W., & Sayler, G. S.
Venue
Environmental Science & Technology
Published
2000-08-09
Volume
34
Issue
18
Pages
3925-3931
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W1990570933
Cited by
260
References
11
FWCI
12.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).