CoChat

Scale-Up of Sonochemical Reactors for Water Treatment

Destaillats, Hugo, Lesko, Timothy M., Knowlton, Michael, Wallace, Henry, Hoffmann, Michael R. · 2001 · Industrial & Engineering Chemistry Research
Cited by 89

The DOI matches its Crossref record.

Abstract

A novel pilot-plant scale sonochemical reactor (UES 4000 C Pilotstation) has been specifically developed for degrading a variety of water contaminants in large-scale applications. We report here the sonochemical degradation of three chemical compounds in aqueous solution: the chlorinated volatile contaminants dichloromethane (DCM) and trichloroethylene (TCE) and the nonvolatile azo dye methyl orange (MO). The flow-through reactor in the Pilotstation consists of four 612 kHz piezoelectric transducers which are driven by a power source operating at 3kW. The sonochemical reaction chamber has a volume of 6 L, while the total capacity of the Pilotstation, including a heat-exchanger unit and a reservoir tank varies from a minimum volume of 7.25 L to a maximum over 45 L. The observed reaction rates for the degradation of these contaminants in the Pilotstation were compared with values determined under similar conditions in small-scale bench reactors in order to evaluate its performance over a wide range of power densities. The pseudo-first-order degradation rate for TCE in the Pilotstation was found to be more than 4 times higher than corresponding smaller values measured in lab-scale reactors. Furthermore, the observed rates for DCM degradation also exceeded those of the small-scale reactors by factors from 3 to 7. The degradation rate of these two chlorinated compounds was faster with decreasing initial concentration in all cases. Experiments with 10 μM MO (aq) in the Pilotstation operating at different total volumes exhibited a linear dependence between the observed rate constants for sonolysis and the applied power density (PD), in the range 67 < PD (W/L) < 414. Steady-state •OH (aq) radical concentrations in each reactor were calculated and were shown to correlate with the applied power density in the vessel. A power budget analysis for the Pilotstation indicates that nearly one-third of the applied power is converted in sonochemical activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ie010110u

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 89

Metadata

Authors
Destaillats, H., Lesko, T. M., Knowlton, M., Wallace, H., & Hoffmann, M. R.
Venue
Industrial & Engineering Chemistry Research
Published
2001-08-04
Volume
40
Issue
18
Pages
3855-3860
ISSN
  • 0888-5885 (ISSN-L)
  • 1520-5045
OpenAlex
W1978896220
Cited by
89
References
0
FWCI
2.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Scale-Up of Sonochemical Reactors for Water Treatment. https://app.cochat.ai/papers/10.1021/ie010110u
The paper
Destaillats, H., Lesko, T. M., Knowlton, M., Wallace, H., & Hoffmann, M. R. (2001). Scale-Up of Sonochemical Reactors for Water Treatment. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie010110u

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.