CoChat

Supercritical CO2 Based Production of Magnetically Responsive Micro- and Nanoparticles for Drug Targeting

Chattopadhyay, Pratibhash, Gupta, Ram B. · 2002 · Industrial & Engineering Chemistry Research
Cited by 80

The DOI matches its Crossref record.

Abstract

Magnetically responsive, controlled-release drug formulations are needed for targeted drug delivery, especially for toxic drugs. A supercritical antisolvent (SAS) technique is used to produce magnetically responsive poly(methyl methacrylate), 50/50 dl -poly(lactide- co -glycolide), and Eudragit RS polymer particles via coprecipitation of the polymer with a suspension of magnetite particles in mineral oil and a fatty acid surfactant, using dichloromethane as the solvent. The SAS technique is again used to precipitate drug-loaded magnetically responsive polymer particles. A modification of the SAS process, the SAS-EM technique developed at Auburn University, is used to produce magnetite-encapsulated polymer nanoparticles of controllable sizes. In SAS-EM, atomization and increased mixing within the supercritical phase is brought about using a surface vibrating at an ultrasonic frequency. Size, morphology, and drug-release kinetics of the obtained particles are studied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ie020205b

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 33

  1. Zaitsev V. S., 1999, J. Colloid Interface Sci., 212, 57, 10.1006/jcis.1998.5993 · DOI · Paper page
  2. Dresco P. A., 1999, Langmuir, 15, 1951, 10.1021/la980971g · DOI · Paper page
  3. Chu B., 1999, Controlled size polymeric microspheres with superparamagnetic cores. PCT Int. Appl
  4. Kresse M., 2000, Iron-containing nanoparticles with double coating and their use in diagnosis and therapy. U.S. Patent 6,048,515
  5. Pulfer S. K., 2000, Biomed. Chem., 211, 225
  6. Vyas S. P., 1989, J. Microencapsulation, 6, 499
  7. Babincova M., 2000, C: J. Biosci.
  8. Viroonchatapan E., 1996, Life Sci., 58, 2261, 10.1016/0024-3205(96)00220-2 · DOI
  9. Ring G. C., 1961, Size of microspheres passing through pulmonary circuit in the dog. Am. J. Physiol
  10. Liberti P. A., 1997, Methods for the manufacture of magnetically responsive particles. U.S. Patent 5,597,531
  11. Kawagachi H., 1996, Colloids Surf. A, 109, 154
  12. Hsieh D. S. T., 1981, Controlled Release Pestic. Pharm. [Proc. Int. Symp.], 7th
  13. Eckert C. A., 1996, Nature (London), 383, 318, 10.1038/383313a0 · DOI · Paper page
  14. Knutson B. L., 1996, Preparation of microparticulates using supercritical fluids. Drugs Pharm. Sci
  15. Chattopadhyay P., 2000, Ind. Eng. Chem. Res., 39, 2289, 10.1021/ie990729k · doi:10.1021/ie990729k
  16. Winters M. A., 1996, J. Pharm. Sci., 85, 594, 10.1021/js950482q · DOI · Paper page
  17. Reverchon E., 1999, Powder Technol., 106, 29, 10.1016/S0032-5910(99)00062-5 · doi:10.1016/s0032-5910(99)00062-5
  18. Steckel H., 1997, Int. J. Pharm., 152, 110, 10.1016/S0378-5173(97)00071-9 · doi:10.1016/s0378-5173(97)00071-9
  19. Shine A. D., 1998, Microencapsulation process using supercritical fluids. PCT Int. Appl
  20. Mueller B. W., 1989, Manufacture of sterile sustained-release drug formulations using liquefied gases. Ger. Offen
  21. Falk R., 1997, J. Controlled Release, 44, 85, 10.1016/S0168-3659(96)01508-8 · DOI · Paper page
  22. Oth M. P., 1989, Int. J. Pharm., 55, 164
  23. Srinath P., 2000, Pharm. Acta Helv., 74, 404, 10.1016/S0031-6865(00)00023-6 · doi:10.1016/s0031-6865(00)00023-6
  24. Gupta R. B., 2002, Pat. Appl. Publ., 37, 20020000681
  25. Chattopadhyay P., 2002, AIChE J., 48, 244, 10.1002/aic.690480207 · DOI
  26. Chattopadhyay P., 2001, Int. J. Pharm., 228, 31, 10.1016/S0378-5173(01)00803-1 · doi:10.1016/s0378-5173(01)00803-1
  27. Chattopadhyay P., 2001, Ind. Eng. Chem. Res., 39, 2289
  28. Randolph T. W., 1993, Biotechnol. Prog., 9, 429, 10.1021/bp00022a010 · DOI · Paper page
  29. Subramaniam B., 1997, Method for a Particle Precipitation and Coating Using Near Critical and Supercritical Antisolvents. U.S. Patent 5,833,891
  30. Yoo H. S., 1999, Pharm. Res., 16, 1118
  31. Kommareddi N. S., 1996, Chem. Mater., 8, 809, 10.1021/cm940485o · DOI
  32. Higuchi T, 1963, J. Pharm. Sci., 52, 1149, 10.1002/jps.2600521211 · DOI
  33. Fessi H., 1978, Int. J. Pharm., 1, 274, 10.1016/0378-5173(78)90024-8 · doi:10.1016/0378-5173(78)90024-8

Cited by

Metadata

Authors
Chattopadhyay, P., & Gupta, R. B.
Venue
Industrial & Engineering Chemistry Research
Published
2002-10-25
Volume
41
Issue
24
Pages
6049-6058
ISSN
  • 0888-5885 (ISSN-L)
  • 1520-5045
OpenAlex
W1965930827
Cited by
80
References
0
FWCI
4.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.