CoChat

Stripping PSA Cycles for CO2 Recovery from Flue Gas at High Temperature Using a Hydrotalcite-Like Adsorbent

Reynolds, Steven P., Ebner, Armin D., Ritter, James A. · 2006 · Industrial & Engineering Chemistry Research
Cited by 113

The DOI matches its Crossref record.

Abstract

A cyclic adsorption process simulator was used to study novel high-temperature pressure swing adsorption (PSA) cycles. Based on the use of a K-promoted hydrotalcite-like (HTlc) adsorbent and six different (vacuum swing) stripping PSA cycles, these cycles were designed to process a typical stack gas effluent at 575 K containing 15 vol % CO 2, 75 vol % N 2, and 10 vol % H 2 O into CO 2 -depleted and CO 2 -enriched streams. More than a thousand (1260) simulations were conducted to the periodic state to study and interpret the effects of the light-product purge-to-feed ratio, the cycle step time, the high-to-low pressure ratio, the heavy-product recycle ratio, and the feed throughput (θ) on the process performance. The cycle configuration was changed from 4-bed 4-step, 4-bed 5-step, and 5-bed 5-step designs that utilized combinations of light-reflux (LR) and/or heavy-reflux (HR) steps, and cocurrent depressurization (CoD) and/or countercurrent depressurization (CnD) steps. The process performance was judged in terms of the CO 2 purity in the heavy product ( y CO 2,HP ), with the CO 2 recovery ( R CO 2 ) and θ both being secondary process performance indicators. Any PSA process with a HR step outperformed any PSA process with only a LR step, regardless of whether a CoD step was added or not. The best performance was obtained from the 4-bed 4-step stripping PSA cycle with HR obtained from the CnD step, with y CO 2,HP = 82.7 vol %, R CO 2 = 17.4%, and θ = 14.4 L STP h -1 kg -1 . The next best performance was obtained from the 5-bed 5-step stripping PSA cycle with LR and HR obtained from LR purge, with y CO 2,HP = 75.5 vol %, R CO 2 = 48.8%, and θ = 23.1 L STP h -1 kg -1 . Overall, this study further substantiated the feasibility of a high-temperature stripping PSA cycle for CO 2 concentration from flue gas using an HTlc adsorbent. It also disclosed the importance of the PSA cycle configuration to the process performance, by gaining an understanding of and appreciation for the use of HR, and it exposed the rigor involved in determining the best PSA cycle sequence for a given application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ie051232f

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 113

Metadata

Authors
Reynolds, S. P., Ebner, A. D., & Ritter, J. A.
Venue
Industrial & Engineering Chemistry Research
Published
2006-05-10
Volume
45
Issue
12
Pages
4278-4294
ISSN
  • 0888-5885 (ISSN-L)
  • 1520-5045
OpenAlex
W2091882400
Cited by
113
References
0
FWCI
12.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stripping PSA Cycles for CO2 Recovery from Flue Gas at High Temperature Using a Hydrotalcite-Like Adsorbent. https://app.cochat.ai/papers/10.1021/ie051232f
The paper
Reynolds, S. P., Ebner, A. D., & Ritter, J. A. (2006). Stripping PSA Cycles for CO2 Recovery from Flue Gas at High Temperature Using a Hydrotalcite-Like Adsorbent. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie051232f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.