The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Experimental Measurement of the Solubility and Diffusivity of CO2 in Room-Temperature Ionic Liquids Using a Transient Thin-Liquid-Film Method
Abstract
In this paper, results from an experimental investigation of carbon dioxide (CO 2 ) solubility and diffusivity in the ionic liquids 1- n -butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([bmim][Tf 2 N]), 1,2-dimethyl-3-propylimidazolium bis(trifluoromethylsulfonyl)imide ([pmmim][Tf 2 N]), 1-butyl-3-methylpyridinium bis(trifluoromethyl sulfonyl)imide ([bmpy][Tf 2 N]), 1-(3,4,5,6-perfluorohexyl)-3-methylimdazolium bis(trifluoromethyl sulfonyl)imide ([perfluoro-hmim][Tf 2 N]), and 1- n -butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF 4 ]) are reported. A transient thin liquid film method was developed, which enables one to determine the Henry's law constant and the diffusivity at low pressure simultaneously. Measurements were performed at temperatures in the range of 283 − 323 K. Henry's law constants were in the range of 25.5−84 bar and were in general agreement with measurements reported by other researchers for these and similar ionic liquids. The entropies and enthalpies of absorption were determined to increase as gas solubility decreased. The measured CO 2 diffusion coefficients in the five ionic liquids were ∼10 -6 cm 2 /s, which is an order of magnitude smaller than the coefficients for CO 2 diffusion in traditional organic solvents. In contrast to the gas solubility results, measured diffusion coefficients were determined to be dependent on the ionic liquid cation as well as the anion. In addition, CO 2 diffusion coefficients were considerably more sensitive to temperature than were CO 2 solubilities in these ionic liquids. Results were used to develop a correlation relating CO 2 diffusion to ionic liquid properties and system temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The properties of gases and liquids
(2001) · Choice Reviews Online · doi:10.5860/choice.38-5036 · Cited by 12,958
Hydrophobic, Highly Conductive Ambient-Temperature Molten Salts
Bonhôte, P., Dias, A.-P., Papageorgiou, N., Kalyanasundaram, K., & Grätzel, M. (1996) · Inorganic Chemistry · doi:10.1021/ic951325x · Cited by 4,358
Ionic liquids. Green solvents for the future
Earle, M. J., & Seddon, K. R. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072071391 · Cited by 2,811
Influence of chloride, water, and organic solvents on the physical properties of ionic liquids
Seddon, K. R., Stark, A., & Torres, M.-J. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072122275 · Cited by 2,293
A short history of ionic liquids—from molten salts to neoteric solvents
Wilkes, J. S. (2002) · Green Chemistry · doi:10.1039/b110838g · Cited by 1,684
Thermophysical Properties of Imidazolium-Based Ionic Liquids
Fredlake, C. P., Crosthwaite, J. M., Hert, D. G., Aki, S. N. V. K., & Brennecke, J. F. (2004) · Journal of Chemical & Engineering Data · doi:10.1021/je034261a · Cited by 1,553
Why Is CO2 So Soluble in Imidazolium-Based Ionic Liquids?
Cadena, C., Anthony, J. L., Shah, J. K., Morrow, T. I., Brennecke, J. F., & Maginn, E. J. (2004) · Journal of the American Chemical Society · doi:10.1021/ja039615x · Cited by 1,518
Ionic liquids: Innovative fluids for chemical processing
Brennecke, J. F., & Maginn, E. J. (2001) · AIChE Journal · doi:10.1002/aic.690471102 · Cited by 1,432
Ackermann, T. (1973) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.1973.84.1-4.224 · Cited by 1,197
Anion Effects on Gas Solubility in Ionic Liquids
Anthony, J. L., Anderson, J. L., Maginn, E. J., & Brennecke, J. F. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp046404l · Cited by 1,058
High-Pressure Phase Behavior of Ionic Liquid/CO2 Systems
Blanchard, L. A., Gu, Z., & Brennecke, J. F. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp003309d · Cited by 1,018
Anthony, J. L., Maginn, E. J., & Brennecke, J. F. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp020631a · Cited by 974
Tokuda, H., Ishii, K., Susan, M. A. B. H., Tsuzuki, S., Hayamizu, K., & Watanabe, M. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp053396f · Cited by 849
Density and viscosity of several pure and water-saturated ionic liquids
Jacquemin, J., Husson, P., Padua, A. A. H., & Majer, V. (2006) · Green Chem. · doi:10.1039/b513231b · Cited by 847
Crosthwaite, J. M., Muldoon, M. J., Dixon, J. K., Anderson, J. L., & Brennecke, J. F. (2005) · The Journal of Chemical Thermodynamics · doi:10.1016/j.jct.2005.03.013 · Cited by 726
Solubilities and Diffusivities of Carbon Dioxide in Ionic Liquids: [bmim][PF6] and [bmim][BF4]
Shiflett, M. B., & Yokozeki, A. (2005) · Industrial & Engineering Chemistry Research · doi:10.1021/ie058003d · Cited by 627
Jacquemin, J., Costa Gomes, M. F., Husson, P., & Majer, V. (2006) · The Journal of Chemical Thermodynamics · doi:10.1016/j.jct.2005.07.002 · Cited by 427
Morgan, D., Ferguson, L., & Scovazzo, P. (2005) · Industrial & Engineering Chemistry Research · doi:10.1021/ie048825v · Cited by 369
Room temperature ionic liquids as replacements for conventional solvents – A review
Marsh, K. N., Deev, A., Wu, A. C.-T., Tran, E., & Klamt, A. (2002) · Korean Journal of Chemical Engineering · doi:10.1007/bf02697140 · Cited by 361
Baltus, R. E., Culbertson, B. H., Dai, S., Luo, H., & DePaoli, D. W. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp036051a · Cited by 333
Self-citationSupported liquid membranes using ionic liquids: study of stability and transport mechanisms
Fortunato, R., Afonso, C. A. M., Reis, M. A. M., & Crespo, J. G. (2004) · Journal of Membrane Science · doi:10.1016/j.memsci.2003.07.028 · Cited by 261
Ferguson, L., & Scovazzo, P. (2007) · Industrial & Engineering Chemistry Research · doi:10.1021/ie0610905 · Cited by 218
Husson, P., Majer, V., & Gomes, M. C. (2003) · Journal of Chemical & Engineering Data · doi:10.1021/je0256277 · Cited by 206
Kroon, M. C., Shariati, A., Costantini, M., van Spronsen, J., Witkamp, G., Sheldon, R. A., & Peters, C. J. (2004) · Journal of Chemical & Engineering Data · doi:10.1021/je049753h · Cited by 190
Costantini, M., Toussaint, V. A., Shariati, A., Peters, C. J., & Kikic, I. (2004) · Journal of Chemical & Engineering Data · doi:10.1021/je049870c · Cited by 136
Room temperature molten polyiodides
Stegemann, H., Rohde, A., Reiche, A., Schnittke, A., & Füllbier, H. (1992) · Electrochimica Acta · doi:10.1016/0013-4686(92)87025-u · Cited by 92
Cited by
Carbon capture and storage update
Boot-Handford, M. E., Abanades, J. C., Anthony, E. J., Blunt, M. J., Brandani, S., Mac Dowell, N., Fernández, J. R., Ferrari, M.-C., Gross, R., Hallett, J. P., et al. (2014) · Energy Environ. Sci. · doi:10.1039/c3ee42350f · Cited by 2,386
A Review of CO2 Capture by Absorption and Adsorption
Yu, C.-H., Huang, C.-H., & Tan, C.-S. (2012) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.05.0132 · Cited by 1,730
An overview of CO2 capture technologies
MacDowell, N., Florin, N., Buchard, A., Hallett, J., Galindo, A., Jackson, G., Adjiman, C. S., Williams, C. K., Shah, N., & Fennell, P. (2010) · Energy & Environmental Science · doi:10.1039/c004106h · Cited by 1,636
State-of-the-Art of CO2Capture with Ionic Liquids
Ramdin, M., de Loos, T. W., & Vlugt, T. J. H. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie3003705 · Cited by 1,073
Gas Solubility in Ionic Liquids
Lei, Z., Dai, C., & Chen, B. (2014) · Chemical Reviews · doi:10.1021/cr300497a · Cited by 1,038
Metadata
- Authors
- Hou, Y., & Baltus, R. E.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-18
- Volume
- 46
- Issue
- 24
- Pages
- 8166-8175
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2004620717
- Cited by
- 257
- References
- 26
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.