The DOI matches its Crossref record.
Carbon Dioxide Capture from Flue Gases Using a Cross-Flow Membrane Contactor and the Ionic Liquid 1-Ethyl-3-methylimidazolium Ethylsulfate
Abstract
Carbon dioxide (CO 2 ) emissions have to be controlled and reduced in order to avoid environmental risks. Membrane processes in combination with the use of ionic liquids are recently under research and development in order to demonstrate a zero solvent emission process for CO 2 capture. In this work, the application of a cross-flow membrane contactor is studied for CO 2 absorption when the ionic liquid 1-ethyl-3-methylimidazolium ethylsulfate is used as solvent. A mathematical model considering a parallel flow configuration is applied for a cross-flow system in order to describe the mass transfer rate. At a macroscopic level, K overall a is calculated considering different mixing models corresponding to plug flow and continuous stirred models and a first order mass transfer rate. A microscopic model based on laminar flow has been applied, obtaining a membrane mass transfer coefficient of k m = 3.78 × 10 −6 m·s −1, which is about five times higher than that obtained in the macroscopic model. The interfacial area, a, allows the comparison of efficiencies between cross-flow and parallel membrane contactor systems in terms of the product ( K overall a ).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Review of CO2 Capture by Absorption and Adsorption
Yu, C.-H., Huang, C.-H., & Tan, C.-S. (2012) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.05.0132 · Cited by 1,730
Combination of ionic liquids with membrane technology: A new approach for CO2 separation
Dai, Z., Noble, R. D., Gin, D. L., Zhang, X., & Deng, L. (2016) · Journal of Membrane Science · doi:10.1016/j.memsci.2015.08.060 · Cited by 559
Recent developments in membrane-based technologies for CO2 capture
Luis, P., Van Gerven, T., & Van der Bruggen, B. (2012) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2012.01.004 · Cited by 529
Self-citationProcess intensification for post-combustion CO2 capture with chemical absorption: A critical review
Wang, M., Joel, A. S., Ramshaw, C., Eimer, D., & Musa, N. M. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.08.083 · Cited by 430
Huang, C.-H., & Tan, C.-S. (2014) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2013.10.0326 · Cited by 390
Metadata
- Authors
- Albo, J., Luis, P., & Irabien, A.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-09-24
- Volume
- 49
- Issue
- 21
- Pages
- 11045-11051
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W1977926975
- Cited by
- 187
- References
- 0
- FWCI
- 13.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon Dioxide Capture from Flue Gases Using a Cross-Flow Membrane Contactor and the Ionic Liquid 1-Ethyl-3-methylimidazolium Ethylsulfate. https://app.cochat.ai/papers/10.1021/ie1014266
- The paper
- Albo, J., Luis, P., & Irabien, A. (2010). Carbon Dioxide Capture from Flue Gases Using a Cross-Flow Membrane Contactor and the Ionic Liquid 1-Ethyl-3-methylimidazolium Ethylsulfate. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie1014266
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.