Tetraethylenepentamine-Modified Siliceous Mesocellular Foam (MCF) for CO2 Capture
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Mesocellular silica foam (MCF) materials with different pore volumes were prepared and modified with tetraethylenepentamine (TEPA) as sorbents for CO 2 capture. The as-prepared sorbents were characterized by XRD, TEM, SEM, nitrogen adsorption/desorption, and FTIR. CO 2 capture performances of the adsorbents were tested in a fixed-bed reactor equipped with an online MS. The results indicated that the pore volume of supports has great effect on the CO 2 capture performance. With the increasing of pore volume as well as the window and cell sizes of the MCF, more TEPA can be loaded into the pores of MCF. For MCF with larger pore volume, more unoccupied space is left after the same amount of TEPA was loaded into the pores. The unoccupied space is beneficial for higher CO 2 uptake because the mass transfer limitation can be reduced to some extent and the interaction between CO 2 and TEPA may be easier. MCF material with largest pore volume exhibited the largest CO 2 uptake of 4.34 mmol/g of adsorbent with a 70 wt % TEPA loading tested by the fixed-bed reactor and at least 4.57 mmol/g tested by thermogravimetric analysis (TGA) under the conditions of 10.0% (v/v) CO 2 in N 2 at 75 °C. Repeated adsorption/desorption cycles revealed that its high CO 2 capacity can be regenerated via temperature swing adsorption and so it may be useful for CO 2 capture via TEPA functionalized MCFs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Post-Combustion CO 2 Capture Using Solid Sorbents: A Review
Samanta, A., Zhao, A., Shimizu, G. K. H., Sarkar, P., & Gupta, R. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie200686q · Cited by 1,889
Cited by
Stability of amine-functionalized CO2 adsorbents: a multifaceted puzzle
Jahandar Lashaki, M., Khiavi, S., & Sayari, A. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00877a · Cited by 460
Yang, M., Guo, L., Hu, G., Hu, X., Xu, L., Chen, J., Dai, W., & Fan, M. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b01311 · Cited by 193
Self-citationWang, L., Rao, L., Xia, B., Wang, L., Yue, L., Liang, Y., DaCosta, H., & Hu, X. (2018) · Carbon · doi:10.1016/j.carbon.2018.01.003 · Cited by 172
Self-citationZeng, W., & Bai, H. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.04.041 · Cited by 65
Metadata
- Authors
- Feng, X., Hu, G., Hu, X., Xie, G., Xie, Y., Lu, J., & Luo, M.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-03-08
- Volume
- 52
- Issue
- 11
- Pages
- 4221-4228
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2320801998
- Cited by
- 124
- References
- 1
- FWCI
- 19.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tetraethylenepentamine-Modified Siliceous Mesocellular Foam (MCF) for CO2 Capture. https://app.cochat.ai/papers/10.1021/ie301946p
- The paper
- Feng, X., Hu, G., Hu, X., Xie, G., Xie, Y., Lu, J., & Luo, M. (2013). Tetraethylenepentamine-Modified Siliceous Mesocellular Foam (MCF) for CO2 Capture. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie301946p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.