Electrochemical Degradation of Methyl Red Using BDD and PbO2 Anodes
The DOI matches its Crossref record.
Abstract
The electrocatalytic properties of lead dioxide (PbO 2 ) and boron-doped diamond (BDD) anodes were compared for the electrochemical incineration of methyl red, an azo dye, using an electrolytic flow cell with parallel-plate electrodes. The effects of several operating parameters such as current density, hydrodynamic conditions, and pH on the degradation rate and current efficiency were determined. The experimental data indicate that, on PbO 2 and BDD anodes, methyl red oxidation takes place by reaction with hydroxyl radicals electrogenerated from water discharge. The electro-oxidation of methyl red was found to behave as a mass-transfer-controlled process, so that the removal rate and current efficiency were enhanced by high flow rates and independent of the pH in the range of 3.0−7.0. It was also observed that the methyl red decay reaction followed pseudo-first-order kinetics with a rate constant that increased slightly with applied current at the PbO 2 anode but was essentially independent of current at the BDD anode. From a comparison of the results, it was found that the BDD anode provided a higher oxidation rate and higher current efficiency; however, the two anodes required almost the same energy consumption for the mineralization of methyl red.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Direct And Mediated Anodic Oxidation of Organic Pollutants
Panizza, M., & Cerisola, G. (2009) · Chemical Reviews · doi:10.1021/cr9001319 · Cited by 2,346
Self-citationElectrochemical Advanced Oxidation Processes: Today and Tomorrow. A Review
Sirés, I., Brillas, E., Oturan, M. A., Rodrigo, M. A., & Panizza, M. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-2783-1 · Cited by 1,943
“2003; Panizza and Cerisola 2009b), dyes (Panizza and Cerisola 2008; Martínez-Huitle and Brillas 2009; Rodriguez et al. 2009; Moreira et al. 2013), pesticides (Polcaro et al.”
BackgroundSelf-citationMartínez-Huitle, C. A., Rodrigo, M. A., Sirés, I., & Scialdone, O. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00361 · Cited by 1,633
Nidheesh, P. V., Zhou, M., & Oturan, M. A. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2017.12.195 · Cited by 1,140
Critical review of electrochemical advanced oxidation processes for water treatment applications
Chaplin, B. P. (2014) · Environ. Sci.: Processes Impacts · doi:10.1039/c3em00679d · Cited by 862
Babuponnusami, A., & Muthukumar, K. (2012) · Chemical Engineering Journal · doi:10.1016/j.cej.2011.12.010 · Cited by 586
Song, S., Fan, J., He, Z., Zhan, L., Liu, Z., Chen, J., & Xu, X. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.01.101 · Cited by 307
Electro-Fenton process for water and wastewater treatment
He, H., & Zhou, Z. (2017) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2017.1405673 · Cited by 303
Metal oxide-coated anodes in wastewater treatment
Subba Rao, A. N., & Venkatarangaiah, V. T. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-013-2313-6 · Cited by 240
“The inclusion of IrO2-Ta2O5 interlayer in Ti/PbO2 electrode increased its service life from 11 to 672 h as determined by the accelerated lifetime test in 1 M H2SO4 under galvanostatic condition (4 A cm−2).”
BackgroundMethodInfluentialZhao, G., Zhang, Y., lei, Y., Lv, B., Gao, J., Zhang, Y., & Li, D. (2010) · Environmental Science & Technology · doi:10.1021/es902336d · Cited by 237
Ansari, A., & Nematollahi, D. (2018) · Water Research · doi:10.1016/j.watres.2018.07.056 · Cited by 226
Ganiyu, S. O., & Martínez‐Huitle, C. A. (2019) · ChemElectroChem · doi:10.1002/celc.201900159 · Cited by 196
Electrochemical treatment of synthetic wastewaters containing Alphazurine A dye
Bensalah, N., Alfaro, M. A. Q., & Martínez-Huitle, C. A. (2009) · Chemical Engineering Journal · doi:10.1016/j.cej.2008.11.031 · Cited by 183
Panizza, M., & Martinez-Huitle, C. A. (2013) · Chemosphere · doi:10.1016/j.chemosphere.2012.09.006 · Cited by 179
Self-citationOturan, N., Ganiyu, S. O., Raffy, S., & Oturan, M. A. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2017.05.062 · Cited by 166
Ammar, H. B., Brahim, M. B., Abdelhédi, R., & Samet, Y. (2016) · Separation and Purification Technology · doi:10.1016/j.seppur.2015.11.027 · Cited by 137
Alam, M. M., Das, A., & Adak, A. (2024) · Water Practice & Technology · doi:10.2166/wpt.2024.280 · Cited by 29
Metadata
- Authors
- Panizza, M., & Cerisola, G.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-08-16
- Volume
- 47
- Issue
- 18
- Pages
- 6816-6820
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W1988983069
- Cited by
- 157
- References
- 0
- FWCI
- 9.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.