The DOI matches its Crossref record.
Metal-Anion Sorption by Chitosan Beads: Equilibrium and Kinetic Studies
Abstract
Chitosan is a well-known biopolymer, whose high nitrogen content confers remarkable ability for the sorption of metal ions from dilute effluents. However, its sorption performance in both equilibrium and kinetic terms is controlled by diffusion processes. Gel bead formation allows an expansion of the polymer network, which improves access to the internal sorption sites and enhances diffusion mechanisms. Molybdate and vanadate recovery using glutaraldehyde cross-linked chitosan beads reaches uptake capacities as high as 7−8 mmol g - 1, depending on the pH. The optimum pH (3−3.5) corresponded to the predominance range of hydrolyzed polynuclear metal forms and optimum electrostatic attraction. While for beads, particle size does not influence equilibrium, for flakes, increasing sorbent radius significantly decreases uptake capacities to 1.5 mmol g - 1 . Sorption kinetics are mainly controlled by intraparticle diffusion for beads, while for flakes the controlling mechanisms are both external and intraparticle diffusions. The gel conditioning increases the intraparticle diffusivity by 3 orders of magnitude: intraparticle diffusivities range between 10 - 13 and 10 - 10 m 2 min - 1, depending on the sorbent size and the conditioning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bhatnagar, A., & Sillanpää, M. (2009) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2009.09.003 · Cited by 718
Equilibrium and kinetic modeling of adsorption of reactive dye on cross-linked chitosan beads
Chiou, M.-S., & Li, H.-Y. (2002) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(02)00030-4 · Cited by 687
Coagulation and flocculation of dye-containing solutions using a biopolymer (Chitosan)
Guibal, E., & Roussy, J. (2007) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2006.08.008 · Cited by 311
Self-citationAdsorption behaviour of methylene blue onto Jordanian diatomite: A kinetic study
Al-Ghouti, M. A., Khraisheh, M. A. M., Ahmad, M. N. M., & Allen, S. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.10.018 · Cited by 300
Microbial Biosorption of Metals
(2011) · Springer eBooks · doi:10.1007/978-94-007-0443-5 · Cited by 269
Metadata
- Authors
- Guibal, E., Milot, C., & Tobin, J. M.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-04-01
- Volume
- 37
- Issue
- 4
- Pages
- 1454-1463
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W1965437356
- Cited by
- 471
- References
- 0
- FWCI
- 22.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal-Anion Sorption by Chitosan Beads: Equilibrium and Kinetic Studies. https://app.cochat.ai/papers/10.1021/ie9703954
- The paper
- Guibal, E., Milot, C., & Tobin, J. M. (1998). Metal-Anion Sorption by Chitosan Beads: Equilibrium and Kinetic Studies. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie9703954
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.