Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 509

The DOI matches its Crossref record.

Monte Carlo Molecular Modeling Studies of Hydrated Li-, Na-, and K-Smectites: Understanding the Role of Potassium as a Clay Swelling Inhibitor

Boek, E. S., Coveney, P. V., Skipper, N. T.·1995·Journal of the American Chemical Society

Abstract

Monte Carlo molecular modeling simulations have been performed to investigate some of the microscopic mechanisms underlying smectite clay swelling. The systems we have studied represent hydrated Wyoming montmorillonites in which the counterions are Li+, Na+, or K+. For each of these three counterions we have conducted a series of 15 simulations in which the water content is increased systematically from 0 to 300 mg/g of clay. In this paper we introduce a new set of interaction potentials that can be used to study clay-water-cation systems and which lend themselves to future studies of intercalated organic molecules. We compare simulation data for the clay layer spacing with experimental swelling curves and find that the level of agreement is striking. Interestingly, in regions where the experimental curves exhibit hysteresis for adsorption/desorption, these loops enclose our calculated data. This indicates that our simulations indeed represent states of thermodynamic equilibrium, conditions which are harder to achieve experimentally. We are therefore content with our choice of atomistic interaction potentials for the current work. Analysis of the microscopic interlayer structure reveals a qualitative difference between Li+ and Na+ on the one hand and K+ on the other. We find that as the water content is increased, both Li+ and Na+ are able to hydrate, thereby becoming detached from the clay surface. In contrast, we find that K+ ions migrate to and bind to the clay surface during our simulations. Therefore ECC ions screen the negatively charged, mutually repelling clay surfaces more effectively than Naf and Lif ions do. The reluctance of K+ ions to fully hydrate will reduce the tendency of K+-saturated clays to expand. Our simulations therefore provide a qualitatively satisfying insight into the role of K+ ions as a clay swelling inhibitor. Indeed, the differences between Na+ and K+ ions displayed in these simulations may also be of more general relevance to colloid chemistry and physiology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja00155a025

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Boek, E. S., Coveney, P. V., & Skipper, N. T.
Venue
Journal of the American Chemical Society
Published
1995-12
Volume
117
Issue
50
Pages
12608-12617
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W1996842905
Cited by
509
References
0
FWCI
6.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.