The DOI matches its Crossref record.
Electronic Transduction of DNA Sensing Processes on Surfaces: Amplification of DNA Detection and Analysis of Single-Base Mismatches by Tagged Liposomes
Abstract
Tagged, negatively charged, liposomes are used to amplify DNA sensing processes. The analyses of the target DNA are transduced electrochemically by using Faradaic impedance spectroscopy, or by microgravimetric measurements with Au-quartz crystals. By one method, a probe oligonucleotide (1) is assembled on Au-electrodes or Au-quartz crystals. The formation of the double-stranded assembly with the analyte DNA (2) is amplified by the association of the 3-oligonucleotide-functionalized liposomes to the sensing interface. The target DNA is analyzed by this method with a sensitivity limit that corresponds to 1 x 10(-12) M. A second method to amplify the sensing of the analyte involves the interaction of the 1-functionalized electrode or Au-quartz crystal with the target DNA sample (2) that is pretreated with the biotinylated oligonucleotide (4). The formation of the three-component double-stranded assembly between 1/2/4 is amplified by the association of avidin and biotin-labeled liposomes to the sensing interfaces. By the secondary association of avidin and biotin-tagged liposomes, a dendritic-type amplification of the analysis of the DNA is accomplished. The analyte DNA (2) is sensed by this method with a sensitivity limit corresponding to 1 x 10(-13) M. The biotin-tagged liposomes are also used to probe and amplify single-base mismatches in an analyte DNA. The 6-oligonucleotide-functionalized Au-electrode or Au-quartz crystal was used to differentiate the single-base mismatch (G) in the mutant (5) from the normal A-containing gene (5a). Polymerase-induced coupling of the biotinylated-C-base to the double-stranded assembly generated between 6 and 5 followed by the association of avidin and biotin-tagged liposomes is used to probe the single base mismatch. The functionalized liposomes provide a particulate building unit for the dendritic amplification of DNA sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Katz, E., & Willner, I. (2003) · Electroanalysis · doi:10.1002/elan.200390114 · Cited by 1,351
Self-citationDNA Biosensors and Microarrays
Sassolas, A., Leca-Bouvier, B. D., & Blum, L. J. (2008) · Chemical Reviews · doi:10.1021/cr0684467 · Cited by 1,246
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Self-citationProspects of conducting polymers in biosensors
Malhotra, B. D., Chaubey, A., & Singh, S. P. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.055 · Cited by 372
Biosensors for clinical diagnostics industry
Malhotra, B. D., & Chaubey, A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00075-3 · Cited by 289
Impedance spectroscopy: Over 35 years of electrochemical sensor optimization
Pejcic, B., & De Marco, R. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.04.025 · Cited by 270
Fluorescein Provides a Resonance Gate for FRET from Conjugated Polymers to DNA Intercalated Dyes
Wang, S., Gaylord, B. S., & Bazan, G. C. (2004) · Journal of the American Chemical Society · doi:10.1021/ja035550m · Cited by 260
Xiao, Y., Qu, X., Plaxco, K. W., & Heeger, A. J. (2007) · Journal of the American Chemical Society · doi:10.1021/ja074218y · Cited by 259
Metadata
- Authors
- Patolsky, F., Lichtenstein, A., & Willner, I.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-05-11
- Volume
- 123
- Issue
- 22
- Pages
- 5194-5205
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2012011961
- Cited by
- 250
- References
- 0
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.