Location of the Fluoride Ion in Tetrapropylammonium Fluoride Silicalite-1 Determined by 1H/19F/29Si Triple Resonance CP, REDOR, and TEDOR NMR Experiments
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
The location of the fluoride ion in tetrapropylammonium fluoride silicalite-1 ([TPA]-F-[Si-MFI]), an as-synthesized siliceous zeolite with the MFI topology, has been unambiguously determined using solid-state NMR experiments alone. With the 1 H→ 29 Si CP-INADEQUATE experiment, the 12 peaks in the highly resolved 29 Si MAS NMR spectrum of [TPA]-F-[Si-MFI] were assigned. Using these peak assignments it was possible to perform 1 H/ 19 F/ 29 Si triple resonance CP, REDOR, and TEDOR experiments to measure F−Si distances and thus locate the fluoride ion. It is covalently bonded to Si-9 in the [4 1 5 2 6 2 ] cage of the zeolite framework and exchanges between two “mirror-related” Si-9 sites, making them equivalent on the NMR time scale. The importance of this result and the general applicability of the approach are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proton-enhanced NMR of dilute spins in solids
Pines, A., Gibby, M. G., & Waugh, J. S. (1973) · The Journal of Chemical Physics · doi:10.1063/1.1680061 · Cited by 2,493
Nuclear Double Resonance in the Rotating Frame
Hartmann, S. R., & Hahn, E. L. (1962) · Physical Review · doi:10.1103/physrev.128.2042 · Cited by 2,236
Principles of High Resolution NMR in Solids
Mehring, M. (1983) · Springer eBooks · doi:10.1007/978-3-642-68756-3 · Cited by 1,981
van Koningsveld, H., van Bekkum, H., & Jansen, J. C. (1987) · Acta Crystallographica Section B Structural Science · doi:10.1107/s0108768187098173 · Cited by 645
Gullion, T., & Schaefer, J. (1989) · Advances in magnetic and optical resonance · doi:10.1016/b978-0-12-025513-9.50009-4 · Cited by 504
Magic-angle spinning and polarization transfer in proton-enhanced NMR
Stejskal, E. O., Schaefer, J., & Waugh, J. S. (1977) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(77)90260-8 · Cited by 468
Transferred-echo double-resonance NMR
Hing, A. W., Vega, S., & Schaefer, J. (1992) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(92)90305-q · Cited by 427
Synthesis of all-silica and high-silica molecular sieves in fluoride media
Camblor, M. A., Villaescusa, L. A., & Díaz-Cabañas, M. J. (1999) · Topics in Catalysis · doi:10.1023/a:1019154304344 · Cited by 383
Alderman, D. W., & Grant, D. M. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90123-9 · Cited by 320
Non-aqueous synthesis of giant crystals of zeolites and molecular sieves
Kuperman, A., Nadimi, S., Oliver, S., Ozin, G. A., Garcés, J. M., & Olken, M. M. (1993) · Nature · doi:10.1038/365239a0 · Cited by 315
Cited by
Solid-State NMR Spectroscopic Methods in Chemistry
Laws, D. D., Bitter, H.-M. L., & Jerschow, A. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020902)41:17<3096::aid-anie3096>3.0.co;2-x · Cited by 341
Solvent-Free Synthesis of Zeolites: Mechanism and Utility
Wu, Q., Meng, X., Gao, X., & Xiao, F.-S. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00057 · Cited by 228
Solvent-Free Synthesis of Zeolites from Anhydrous Starting Raw Solids
Wu, Q., Liu, X., Zhu, L., Ding, L., Gao, P., Wang, X., Pan, S., Bian, C., Meng, X., Xu, J., et al. (2015) · Journal of the American Chemical Society · doi:10.1021/ja5124013 · Cited by 219
Platelike MFI Crystals with Controlled Crystal Faces Aspect Ratio
Dai, W., Kouvatas, C., Tai, W., Wu, G., Guan, N., Li, L., & Valtchev, V. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.0c11784 · Cited by 195
Adsorption of Water and Ethanol in MFI-Type Zeolites
Zhang, K., Lively, R. P., Noel, J. D., Dose, M. E., McCool, B. A., Chance, R. R., & Koros, W. J. (2012) · Langmuir · doi:10.1021/la301122h · Cited by 191
Metadata
- Authors
- Fyfe, C. A., Brouwer, D. H., Lewis, A. R., & Chézeau, J.-M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-06-20
- Volume
- 123
- Issue
- 28
- Pages
- 6882-6891
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2091719910
- Cited by
- 159
- References
- 33
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Location of the Fluoride Ion in Tetrapropylammonium Fluoride Silicalite-1 Determined by 1H/19F/29Si Triple Resonance CP, REDOR, and TEDOR NMR Experiments. https://app.cochat.ai/papers/10.1021/ja010532v
- The paper
- Fyfe, C. A., Brouwer, D. H., Lewis, A. R., & Chézeau, J.-M. (2001). Location of the Fluoride Ion in Tetrapropylammonium Fluoride Silicalite-1 Determined by 1H/19F/29Si Triple Resonance CP, REDOR, and TEDOR NMR Experiments. Journal of the American Chemical Society. https://doi.org/10.1021/ja010532v
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.