CoChat

Proximity Effects in Monolayer Films: Kinetic Analysis of Amide Bond Formation at the Air−Water Interface Using 1H NMR Spectroscopy

Kumar, Jaya K., Oliver, John S. · 2002 · Journal of the American Chemical Society
Cited by 32

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The kinetics of amide bond formation in a monolayer film has been studied by proton NMR spectroscopy. Compression of a hexadecyl thioester of N-acetyl glycine (1) and a hexadecyl amide of glycine (2) at the air-water interface produces a single dipeptide product (4) that remains at the surface once formed. Extraction of the reaction mixture from the interface, followed by (1)H NMR spectroscopy, provides quantitative data on the rate of product formation. The kinetics of this reaction was examined as a function of surface pressure, subphase pH, and temperature. The monolayer provides an effective molarity for the reaction of approximately 500 M as compared to the bimolecular reaction of 1 and 4 in chloroform solution. The first-order rate constant for the reaction of 1 and 2 in the monolayer is less than 70-fold slower than k(cat) for condensation of the first amide bond in the enzymatic synthesis of the cyclic antibiotic gramicidin S by gramicidin S synthetase. Activation energies of the reaction were extracted from the temperature dependence of the rate constants of the reaction and are 9.9 +/- 1.0 and 2.1 +/- 0.2 kcal/mol for the chloroform solution and monolayer reactions, respectively. The pK(a) of 2 in the monolayer was estimated to be approximately 0.5 pK(a) units lower than that of related amines in solution. The lower pK(a) at the interface as compared to that in solution may be ascribed to increased electrostatic repulsion at the interface relative to solution. The rate of reaction in the monolayer was also followed by monitoring changes in surface area as a function of time. The rate constant for the reaction of 1 and 4 as determined by changes in surface area differs significantly from the rate determined by NMR. The results indicate that measurements of surface area versus time may yield erroneous rate constants for reactions in monolayers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja0175237

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Kumar, J. K., & Oliver, J. S.
Venue
Journal of the American Chemical Society
Published
2002-08-30
Volume
124
Issue
38
Pages
11307-11314
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2046113010
Cited by
32
References
2
FWCI
2.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.