The DOI matches its Crossref record.
Electrochemical Sensing in Microfluidic Systems Using Electrogenerated Chemiluminescence as a Photonic Reporter of Redox Reactions
Abstract
This paper describes a microfluidics-based sensing system that relies on electrochemical detection and electrogenerated chemiluminescent (ECL) reporting. The important result is that the ECL reporting reaction is chemically decoupled from the electrochemical sensing reaction. That is, the electrochemical sensing reaction does not participate directly in the ECL process, but because electrochemical cells require charge balance, the sensing and ECL reactions are electrically coupled. This provides a convenient and sensitive means for direct photonic readout of electrochemical reactions that do not directly participate in an ECL reaction and thus broadens the spectrum of redox compounds that can be detected by ECL. The approach can be implemented in either a two-electrode or bipolar (single-electrode) configuration. By manipulating the placement and dimensions of the conductors, the photonic response can be enhanced. The system is used to electrochemically detect benzyl viologen present in solution and report its presence via Ru(bpy)(3)(2+) (bpy = 2,2'-bipyridine) luminescence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Modern Strategies in Electroorganic Synthesis
Yoshida, J.-I., Kataoka, K., Horcajada, R., & Nagaki, A. (2008) · Chemical Reviews · doi:10.1021/cr0680843 · Cited by 1,417
Applications and trends in electrochemiluminescence
Hu, L., & Xu, G. (2010) · Chemical Society Reviews · doi:10.1039/b923679c · Cited by 1,104
Potential-Resolved Multicolor Electrochemiluminescence for Multiplex Immunoassay in a Single Sample
Guo, W., Ding, H., Gu, C., Liu, Y., Jiang, X., Su, B., & Shao, Y. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b09422 · Cited by 364
Nanomaterials-based sensitive electrochemiluminescence biosensing
Chen, Y., Zhou, S., Li, L., & Zhu, J.-J. (2017) · Nano Today · doi:10.1016/j.nantod.2016.12.013 · Cited by 337
Lin, X., Zheng, L., Gao, G., Chi, Y., & Chen, G. (2012) · Analytical Chemistry · doi:10.1021/ac300875x · Cited by 93
Metadata
- Authors
- Zhan, W., Alvarez, J., & Crooks, R. M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-10-11
- Volume
- 124
- Issue
- 44
- Pages
- 13265-13270
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2091685279
- Cited by
- 223
- References
- 0
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Sensing in Microfluidic Systems Using Electrogenerated Chemiluminescence as a Photonic Reporter of Redox Reactions. https://app.cochat.ai/papers/10.1021/ja020907s
- The paper
- Zhan, W., Alvarez, J., & Crooks, R. M. (2002). Electrochemical Sensing in Microfluidic Systems Using Electrogenerated Chemiluminescence as a Photonic Reporter of Redox Reactions. Journal of the American Chemical Society. https://doi.org/10.1021/ja020907s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.