The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Detection of Nitroaromatic Explosives Based on Photoluminescent Polymers Containing Metalloles
Abstract
The synthesis, spectroscopic characterization, and fluorescence quenching efficiency of polymers and copolymers containing tetraphenylsilole or tetraphenylgermole with Si-Si, Ge-Ge, and Si-Ge backbones are reported. Poly(tetraphenyl)germole, 2, was synthesized from the reduction of dichloro(tetraphenyl)germole with 2 equivs of Li. Silole-germole alternating copolymer 3 was synthesized by coupling dilithium salts of tetraphenylsilole dianion with dichloro(tetraphenyl)germole. Other tetraphenylmetallole-silane copolymers, 4-12, were synthesized through the Wurtz-type coupling of the dilithium salts of the tetraphenylmetallole dianion and corresponding dichloro(dialkyl)silanes. The molecular weights (M(w)) of these metallole-silane copolymers are in the range of 4000 approximately 6000. Detection of nitroaromatic molecules, such as nitrobenzene (NB), 2,4-dinitrotoluene (DNT), 2,4,6-trinitrotoluene (TNT), and picric acid (PA), has been explored. A linear Stern-Volmer relationship was observed for the first three analytes, but not for picric acid. Fluorescence spectra of polymetalloles or metallole-silane copolymers obtained in either toluene solutions or thin polymer films displayed no shift in the maximum of the emission wavelength. This suggests that the polymetalloles or metallole-silanes exhibit neither pi-stacking of polymer chains nor excimer formation. Fluorescence lifetimes of polymetalloles and metallole-silanes were measured both in the presence and absence of TNT, and tau(o)/tau is invariant. This requires that photoluminescence quenching occurs by a static mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Cited by
Aggregation‐Induced Emission: The Whole Is More Brilliant than the Parts
Mei, J., Hong, Y., Lam, J. W. Y., Qin, A., Tang, Y., & Tang, B. Z. (2014) · Advanced Materials · doi:10.1002/adma.201401356 · Cited by 3,381
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Optical explosives detection: from color changes to fluorescence turn-on
Germain, M. E., & Knapp, M. J. (2009) · Chemical Society Reviews · doi:10.1039/b809631g · Cited by 1,046
Wang, M., Zhang, G., Zhang, D., Zhu, D., & Tang, B. Z. (2010) · Journal of Materials Chemistry · doi:10.1039/b921610c · Cited by 852
Dasary, S. S. R., Singh, A. K., Senapati, D., Yu, H., & Ray, P. C. (2009) · Journal of the American Chemical Society · doi:10.1021/ja905134d · Cited by 722
Sun, C.-Y., Wang, X.-L., Zhang, X., Qin, C., Li, P., Su, Z.-M., Zhu, D.-X., Shan, G.-G., Shao, K.-Z., Wu, H., et al. (2013) · Nature Communications · doi:10.1038/ncomms3717 · Cited by 573
Wu, S., Lin, Y., Liu, J., Shi, W., Yang, G., & Cheng, P. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201707169 · Cited by 528
Luminogenic polymers with aggregation-induced emission characteristics
Qin, A., Lam, J. W. Y., & Tang, B. Z. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.08.002 · Cited by 441
Nanosensors for trace explosive detection
Senesac, L., & Thundat, T. G. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70017-8 · Cited by 368
Array sensing using optical methods for detection of chemical and biological hazards
Diehl, K. L., & Anslyn, E. V. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60136f · Cited by 332
Riskin, M., Tel-Vered, R., Bourenko, T., Granot, E., & Willner, I. (2008) · Journal of the American Chemical Society · doi:10.1021/ja711278c · Cited by 295
Highly Selective and Sensitive Fluorescent Paper Sensor for Nitroaromatic Explosive Detection
Ma, Y., Li, H., Peng, S., & Wang, L. (2012) · Analytical Chemistry · doi:10.1021/ac302138c · Cited by 283
Khatua, S., Goswami, S., Biswas, S., Tomar, K., Jena, H. S., & Konar, S. (2015) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b01773 · Cited by 258
Chen, P., Sukcharoenchoke, S., Ryu, K., Gomez de Arco, L., Badmaev, A., Wang, C., & Zhou, C. (2010) · Advanced Materials · doi:10.1002/adma.200904005 · Cited by 166
Ma, J., Lin, T., Pan, X., & Wang, W. (2014) · Chemistry of Materials · doi:10.1021/cm501590w · Cited by 59
Metadata
- Authors
- Sohn, H., Sailor, M. J., Magde, D., & Trogler, W. C.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-03-06
- Volume
- 125
- Issue
- 13
- Pages
- 3821-3830
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2082816548
- Cited by
- 673
- References
- 1
- FWCI
- 8.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.