The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An Oxygen Cathode Operating in a Physiological Solution
Abstract
We report the electroreduction of O(2) to water under physiological conditions (pH 7.4, 0.15 M NaCl, 37.5 degrees C) at a current density of 5 mA cm(-2) and at a potential only 0.18 V reducing versus that of the reversible O(2)/H(2)O electrode at pH 7.4. The immobilized electrocatalyst enabling the reduction is the electrostatic adduct of bilirubin oxidase from Myrothecium verrucaria, a polyanion at pH >4.1, and the polycationic redox copolymer of polyacrylamide and poly (N-vinylimidazole) complexed with [Os (4,4'-dichloro-2,2'-bipyridine)(2)Cl](+/2+), cross-linked on carbon cloth. The current density of the rotating electrodes was O(2) transport limited up to 8.8 mA cm(-2); their kinetic limit was reached at 9.1 mA cm(-2). The operational life of the electrodes depended on their angular velocity, which defined not only the current density but also the mechanical shear stress stripping the electrocatalyst. When the electrodes were rotated at 300 rpm and were poised at -256 mV versus the potential of the reversible O(2)/H(2)O electrode, their 2.4 mA cm(-2) initial current density decreased to 1.3 mA cm(-2) after 6 days of continuous operation at 37.5 degrees C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multicopper oxidases and oxygenases
Solomon, E. I., Sundaram, U. M., & Machonkin, T. E. (1996) · Chemical Reviews · doi:10.1021/cr950046o · Cited by 3,664
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationBiofuel cells and their development
Bullen, R. A., Arnot, T. C., Lakeman, J. B., & Walsh, F. C. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.030 · Cited by 1,011
Enzymes as Working or Inspirational Electrocatalysts for Fuel Cells and Electrolysis
Cracknell, J. A., Vincent, K. A., & Armstrong, F. A. (2008) · Chemical Reviews · doi:10.1021/cr0680639 · Cited by 988
Nanostructured electrode materials for electrochemical energy storage and conversion
Manthiram, A., Vadivel Murugan, A., Sarkar, A., & Muraliganth, T. (2008) · Energy & Environmental Science · doi:10.1039/b811802g · Cited by 638
Fernández, J. L., Walsh, D. A., & Bard, A. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0449729 · Cited by 623
More Sustainable Approaches for the Synthesis of N-Based Heterocycles
Candeias, N. R., Branco, L. C., Gois, P. M. P., Afonso, C. A. M., & Trindade, A. F. (2009) · Chemical Reviews · doi:10.1021/cr800462w · Cited by 403
Extended lifetime biofuel cells
Moehlenbrock, M. J., & Minteer, S. D. (2008) · Chemical Society Reviews · doi:10.1039/b708013c · Cited by 351
A high-power glucose/oxygen biofuel cell operating under quiescent conditions
Sakai, H., Nakagawa, T., Tokita, Y., Hatazawa, T., Ikeda, T., Tsujimura, S., & Kano, K. (2009) · Energy Environ. Sci. · doi:10.1039/b809841g · Cited by 332
Metadata
- Authors
- Mano, N., Kim, H.-H., Zhang, Y., & Heller, A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-05-10
- Volume
- 124
- Issue
- 22
- Pages
- 6480-6486
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2023476535
- Cited by
- 215
- References
- 1
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.