The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
ZP4, an Improved Neuronal Zn2+ Sensor of the Zinpyr Family
Abstract
A second-generation fluorescent sensor for Zn(2+) from the Zinpyr family, ZP4, has been synthesized and characterized. ZP4 (Zinpyr-4, 9-(o-carboxyphenyl)-2-chloro-5-[2-(bis(2-pyridylmethyl)aminomethyl)-N-methylaniline]-6-hydroxy-3-xanthanone) is prepared via a convergent synthetic strategy developed from previous studies with these compounds. ZP4, like its predecessors, has excitation and emission wavelengths in the visible range ( approximately 500 nm), a dissociation constant (K(d)) for Zn(2+) of less than 1 nM and a high quantum yields (Phi = approximately 0.4), making it well suited for biological applications. A 5-fold fluorescent enhancement is observed under simulated physiological conditions corresponding to the binding of the Zn(2+) cation to the sensor, which inhibits a photoinduced electron transfer (PET) quenching pathway. The metal-binding stereochemistry of ZP4 was evaluated through the synthesis and X-ray structural characterization of [M(BPAMP)(H(2)O)(n)](+) complexes, where BPAMP is [2-(bis(2-pyridylmethyl)aminomethyl)-N-methylaniline]-phenol and M = Mn(2+), Zn(2+) (n = 1) or Cu(2+) (n = 0).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Femtomolar Sensitivity of Metalloregulatory Proteins Controlling Zinc Homeostasis
Outten, C. E., & O'Halloran, A. T. V. (2001) · Science · doi:10.1126/science.1060331 · Cited by 1,489
Effects of Angiogenesis Inhibitors on Multistage Carcinogenesis in Mice
Bergers, G., Javaherian, K., Lo, K.-M., Folkman, J., & Hanahan, D. (1999) · Science · doi:10.1126/science.284.5415.808 · Cited by 988
Cited by
Synthetic fluorescent sensors for studying the cell biology of metals
Domaille, D. W., Que, E. L., & Chang, C. J. (2008) · Nature Chemical Biology · doi:10.1038/nchembio.69 · Cited by 1,081
Jiang, P., & Guo, Z. (2004) · Coordination Chemistry Reviews · doi:10.1016/j.cct.2003.10.013 · Cited by 989
The biological inorganic chemistry of zinc ions
Krężel, A., & Maret, W. (2016) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2016.04.010 · Cited by 768
Small-Molecule Fluorescent Sensors for Investigating Zinc Metalloneurochemistry
Nolan, E. M., & Lippard, S. J. (2009) · Accounts of Chemical Research · doi:10.1021/ar8001409 · Cited by 620
Self-citationZinc sensing for cellular application
Kikuchi, K., Komatsu, K., & Nagano, T. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.02.007 · Cited by 320
Metadata
- Authors
- Burdette, S. C., Frederickson, C. J., Bu, W., & Lippard, S. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-01-22
- Volume
- 125
- Issue
- 7
- Pages
- 1778-1787
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1999761740
- Cited by
- 363
- References
- 2
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.