Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 191

The DOI matches its Crossref record.

High-Efficiency Poly(p-phenylenevinylene)-Based Copolymers Containing an Oxadiazole Pendant Group for Light-Emitting Diodes

Jin, Sung-Ho, Kim, Mock-Yeon, Kim, Jin Young, Lee, Kwanghee, Gal, Yeong-Soon·2004·Journal of the American Chemical Society

Abstract

A new series of high brightness and luminance efficient poly(p-phenylenevinylene) (PPV)-based electroluminescent (EL) polymers, poly[2-[4-[5-(4-(3,7-dimethyloctyloxy)phenyl)-1,3,4-oxadiazole-2-yl]phenyloxy]-1,4-phenylenevinylene] (Oxa-PPV), poly[2-[2-((3,7-dimethyloctyl)oxy)phenoxy]-1,4-phenylenevinylene] (DMOP-PPV), and their corresponding random copolymers, poly[[2-[4-[5-(4-(3,7-dimethyloctyloxy)phenyl)-1,3,4-oxadiazole-2-yl]phenyloxy]-1,4-phenylenevinylene]-co-[2-[2-((3,7-dimethyloctyl)oxy) phenoxy]-1,4-phenylenevinylene]] (Oxa-PPV-co-DMOP-PPV), with an electron-deficient 1,3,4-oxadiazole unit on the side groups, were synthesized through the Gilch polymerization method. The newly designed and synthesized asymmetric molecular structures of Oxa-PPV, DMOP-PPV, and Oxa-PPV-co-DMOP-PPV were completely soluble in common organic solvents, and defect-free optical thin film was easily spin-coated onto the indium tin oxide (ITO) substrate. Oxa-PPV shows a high glass transition temperature (T(g)), which might be an advantage for long time operation of polymer light-emitting diodes (PLEDs). Double-layer LEDs with an ITO/PEDOT/polymer/Al configuration were fabricated by using those polymers. Electrooptical properties and device performance could be adjusted by introducing the Oxa-PPV content in the copolymers. The emission colors could be tuned from green to yellowish-orange via intramolecular energy transfer. The improved device performance of Oxa-PPV over DMOP-PPV and Oxa-PPV-co-DMOP-PPV may be due to better electron injection and charge balance between holes and electrons and also efficient intramolecular energy transfer from 1,3,4-oxadiazole units to PPV backbones. The maximum brightness and the luminance efficiency of Oxa-PPV were up to 19395 cd/m(2) at 14 V and 21.1 cd/A at 5930 cd/m(2). The maximum luminance efficiency of Oxa-PPV is ranked the highest value among the PPV derivatives to date.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja036955+

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Jin, S.-H., Kim, M.-Y., Kim, J. Y., Lee, K., & Gal, Y.-S.
Venue
Journal of the American Chemical Society
Published
2004-02-07
Volume
126
Issue
8
Pages
2474-2480
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2052847121
Cited by
191
References
0
FWCI
16.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.