The DOI matches its Crossref record.
Infrared Photodissociation Spectroscopy of Electrosprayed Ions in a Fourier Transform Mass Spectrometer
Abstract
Previous gas-phase methods for infrared photodissociation spectroscopy (IRPD) require sample volatility. Our method instead uses electrospray ionization to introduce even large nonvolatile molecules into a Fourier transform mass spectrometer, where extended (>15 s) ion storage makes possible high sensitivity spectral measurements with an OPO laser over a range of 3050-3800 cm(-1). The spectra of 22 gaseous proton-bound amino acid complexes are generally correlated with the H-stretching frequencies established for O-H and N-H functional groups in solution. For theoretical structure predictions of the Gly2H+ and N-acylated Asp2H+ dimers, IRPD spectra clearly differentiate between the predicted lowest energy conformers. In contrast to solution, in the gas phase the glycine zwitterion is approximately 20 kcal/mol less stable than the neutral; however, glycine is clearly zwitterionic in the gaseous GlyLysH+ dimer. The level of theory is inadequate for the larger Lys2H+ dimer, as all low energy predicted structures have free carboxyl O-H groups, in contrast to the IR spectrum. IRPD appears to be a promising new technique for providing unique information on a broad range of biomolecular and other gaseous ions, especially on noncovalent bonding involving O-H and N-H groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gas-phase infrared multiple photon dissociation spectroscopy of mass-selected molecular ions
Oomens, J., Sartakov, B. G., Meijer, G., & von Helden, G. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.05.009 · Cited by 535
Breuker, K., & McLafferty, F. W. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807005105 · Cited by 423
Self-citationInfrared multiple photon dissociation spectroscopy of trapped ions
Polfer, N. C. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00171f · Cited by 311
Serine Octamers: Cluster Formation, Reactions, and Implications for Biomolecule Homochirality
Nanita, S. C., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501328 · Cited by 184
Metadata
- Authors
- Oh, H.-B., Lin, C., Hwang, H. Y., Zhai, H., Breuker, K., Zabrouskov, V., Carpenter, B. K., & McLafferty, F. W.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-02-24
- Volume
- 127
- Issue
- 11
- Pages
- 4076-4083
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2034800174
- Cited by
- 159
- References
- 0
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.