The DOI matches its Crossref record.
Truly Quantitative XPS Characterization of Organic Monolayers on Silicon: Study of Alkyl and Alkoxy Monolayers on H−Si(111)
Abstract
The quantitative characterization of the chemical composition (bonding at grafted and ungrafted sites, surface coverage) is a key issue for the application of silicon-organic monolayer hybrid interfaces. The primary purpose of this article is to demonstrate that X-ray photoelectron spectroscopy (XPS) requires to be truly quantitative to deal with two main questions. The first one is accounting for X-ray photodiffraction (XPD), a well-known phenomenon that is responsible for azimuthal variations of the XPS signal intensity. A simple procedure is proposed to account for XPD in angle-resolved measurements. The second critical point concerns the choice of photoelectron attenuation lengths (AL). This article demonstrates that n-alkanethiol self-assembled monolayers on Au(111) can be used as a reference system to derive the effective monolayer thickness on silicon substrates and that one may use the empirical relationship established by Laibinis and co-workers to calculate the relevant ALs (Laibinis, P. E.; Bain, C. D.; Whitesides, G. M. J. Phys. Chem. 1991, 95, 7017). A self-consistent approach is presented to justify the above assertions and to give a complete compositional description of alkyl and alkoxy monolayers directly grafted on atomically flat H-Si(111) surfaces. Direct evidences are provided that a Si-C and a Si-O-C linkage is formed, respectively, after reaction with decene and decanol and that the ungrafted sites remain saturated with H atoms. Moreover, the quantitative spectra analysis of satellite peaks at fixed polar angle and three independent angle-resolved Si2p and C1s spectra all give the same surface coverage very close to its theoretical limit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Large-Area, Ensemble Molecular Electronics: Motivation and Challenges
Vilan, A., Aswal, D., & Cahen, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00595 · Cited by 395
Ciampi, S., Harper, J. B., & Gooding, J. J. (2010) · Chemical Society Reviews · doi:10.1039/b923890p · Cited by 310
Functionalization of Acetylene-Terminated Monolayers on Si(100) Surfaces: A Click Chemistry Approach
Ciampi, S., Böcking, T., Kilian, K. A., James, M., Harper, J. B., & Gooding, J. J. (2007) · Langmuir · doi:10.1021/la701035g · Cited by 286
Gu, J., Yan, Y., Young, J. L., Steirer, K. X., Neale, N. R., & Turner, J. A. (2016) · Nature Materials · doi:10.1038/nmat4511 · Cited by 261
Characteristics of oat hull based biosorbent for natural gas dehydration in a PSA process
Ghanbari, S., & Niu, C. H. (2019) · Journal of Natural Gas Science and Engineering · doi:10.1016/j.jngse.2018.11.014 · Cited by 29
Characterization of a high-performance biosorbent for natural gas dehydration
Ghanbari, S., & Niu, C. H. (2018) · Energy & Fuels · doi:10.1021/acs.energyfuels.8b02665 · Cited by 17
Metadata
- Authors
- Wallart, X., Henry de Villeneuve, C., & Allongue, P.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-05-06
- Volume
- 127
- Issue
- 21
- Pages
- 7871-7878
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2071432040
- Cited by
- 206
- References
- 0
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.