The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Selective Calcium Ion Sensing with a Bichromophoric Squaraine Foldamer
Abstract
Several squaraine tethered bichromophoric podand systems 1a-d and a monochromophoric analogue 2 were prepared and characterized. Among these, the bichromophore, 1b, containing five oxygen atoms in the flexible podand moiety was found to specifically bind Ca(2+) in the presence of other metal ions such as K(+), Na(+), and Mg(2+). The selective binding of Ca(2+) is clear from the absorption and emission spectral changes as well as by the visual color change of 1b from light-blue to an intense purple-blue. Benesi-Hildebrand and Job plots confirmed a 1:1 binding between 1b and Ca(2+). Signaling of the binding event is achieved by the cation-induced folding of the bichromophore and the resultant exciton coupling between the squaraine chromophores. The monochromophoric squaraine dye 2 failed to give optical signals upon Ca(2+) binding, due to the absence of exciton interaction in the bound complex. Titration of the folded complex 9 with EDTA released the metal ion from the complex, thereby regaining the original absorption and emission properties of the bichromophore. The squaraine foldamer 1b reported here is the first example of a selective chromogenic Ca(2+) sensor, which works on the principle of exciton interaction in the folded Ca(2+) complex of a bichromophore, the optical properties of which are similar to those of the "H"-type aggregates of analogous squaraine dyes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The exciton model in molecular spectroscopy
Kasha, M., Rawls, H. R., & Ashraf El-Bayoumi, M. (1965) · Pure and Applied Chemistry · doi:10.1351/pac196511030371 · Cited by 4,253
Cited by
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Digital Information Processing in Molecular Systems
Szaciłowski, K. (2008) · Chemical Reviews · doi:10.1021/cr068403q · Cited by 827
Sreejith, S., Divya, K. P., & Ajayaghosh, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803194 · Cited by 269
Self-citationA Coumarin-Derived Fluorescence Probe Selective for Magnesium
Ray, D., & Bharadwaj, P. K. (2008) · Inorganic Chemistry · doi:10.1021/ic702388z · Cited by 269
Sreejith, S., Divya, K. P., & Ajayaghosh, A. (2008) · Angewandte Chemie · doi:10.1002/ange.200803194 · Cited by 256
Self-citation
Metadata
- Authors
- Arunkumar, E., Ajayaghosh, A., & Daub, J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-02-16
- Volume
- 127
- Issue
- 9
- Pages
- 3156-3164
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1999730214
- Cited by
- 193
- References
- 1
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective Calcium Ion Sensing with a Bichromophoric Squaraine Foldamer. https://app.cochat.ai/papers/10.1021/ja045760e
- The paper
- Arunkumar, E., Ajayaghosh, A., & Daub, J. (2005). Selective Calcium Ion Sensing with a Bichromophoric Squaraine Foldamer. Journal of the American Chemical Society. https://doi.org/10.1021/ja045760e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.