The DOI matches its Crossref record.
Perturbation of Fluorescence by Nonspecific Interactions between Anionic Poly(phenylenevinylene)s and Proteins: Implications for Biosensors
Abstract
The use of anionic water-soluble conjugated polymers (CPs) for sensing the presence of avidin by use of a biotin-modified fluorescence quencher was studied. The molecules involved in the study included poly[2-methoxy-5-(3'-propyloxysulfonate)-1,4-phenylenevinylene] with either lithium (Li+-MPS-PPV) or sodium (Na(+)-MPS-PPV) countercations, the well-defined oligomer pentasodium 1,4-bis(4'(2",4"-bis(butoxysulfonate)-styryl)-styryl)2-butoxysulfonate-5-methoxybenzene (5R5-), the quenchers N-methyl-4,4'-pyridylpyridinium iodide (mMV+) and [N-(biotinoyl)-N'-(acetyl 4,4'-pyridylpyridinium iodide)] ethylenediamine (BPP+), which contains a molecular recognition fragment (biotin) attached to a unit that accepts an electron from a CP excited state, and the proteins avidin, tau, BSA, and pepsin A. Fluorescence quenching experiments were examined in a variety of conditions. Experiments carried out in water and in ammonium carbonate buffer (which ensures avidin/biotin complexation) reveal that nonspecific interactions between the CP and the proteins cause substantial perturbations on the CP fluorescence. The overall findings are not consistent with a simple mechanism whereby avidin complexation of BPP+ leads to encapsulation of the quencher molecule and recovery of Li+-MPS-PPV fluorescence. Instead, we propose that binding of BPP+ to avidin results in the quenching unit attaching to a positively charged macromolecule. Electrostatic attraction to the negatively charged conjugated polymer results in closer proximity to the quencher. Therefore, more enhanced fluorescence quenching is observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Chemical Sensors Based on Amplifying Fluorescent Conjugated Polymers
Thomas, S. W., Joly, G. D., & Swager, T. M. (2007) · Chemical Reviews · doi:10.1021/cr0501339 · Cited by 4,198
Conjugated Polyelectrolytes: Synthesis, Photophysics, and Applications
Jiang, H., Taranekar, P., Reynolds, J. R., & Schanze, K. S. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805456 · Cited by 734
Array-Based Sensing of Proteins Using Conjugated Polymers
Miranda, O. R., You, C.-C., Phillips, R., Kim, I.-B., Ghosh, P. S., Bunz, U. H. F., & Rotello, V. M. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0737927 · Cited by 267
Fan, L.-J., Zhang, Y., Murphy, C. B., Angell, S. E., Parker, M. F. L., Flynn, B. R., & Jones, W. E. (2009) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2008.03.008 · Cited by 260
Metadata
- Authors
- Dwight, S. J., Gaylord, B. S., Hong, J. W., & Bazan, G. C.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-12-01
- Volume
- 126
- Issue
- 51
- Pages
- 16850-16859
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1964927509
- Cited by
- 178
- References
- 0
- FWCI
- 8.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.