The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Structural Insights into Nonheme Alkylperoxoiron(III) and Oxoiron(IV) Intermediates by X-ray Absorption Spectroscopy
Abstract
Transient mononuclear low-spin alkylperoxoiron(III) and oxoiron(IV) complexes that are relevant to the activation of dioxygen by nonheme iron enzymes have been generated from synthetic iron(II) complexes of neutral tetradentate (TPA) and pentadentate (N4Py, Bn-TPEN) ligands and structurally characterized by means of Fe K-edge X-ray absorption spectroscopy (XAS). Notable features obtained from fits of the EXAFS region are Fe-O bond lengths of 1.78 A for the alkylperoxoiron(III) intermediates and 1.65-1.68 A for the oxoiron(IV) intermediates, reflecting different strengths in the Fe-O pi interactions. These differences are also observed in the intensities of the 1s-to-3d transitions in the XANES region, which increase from 4 units for the nearly octahedral iron(II) precursor to 9-15 units for the alkylperoxoiron(III) intermediates to 25-29 units for the oxoiron(IV) species.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coulter, E. D., Emerson, J. P., Kurtz, D. M., & Cabelli, D. E. (2000) · Journal of the American Chemical Society · doi:10.1021/ja005583r · Cited by 101
Emerson, J. P., Coulter, E. D., Cabelli, D. E., Phillips, R. S., & Kurtz, D. M. (2002) · Biochemistry · doi:10.1021/bi0119159 · Cited by 89
Nivière, V., Asso, M., Weill, C. O., Lombard, M., Guigliarelli, B., Favaudon, V., & Houée-Levin, C. (2004) · Biochemistry · doi:10.1021/bi035698i · Cited by 65
Cited by
Wang, Z., Qiu, W., Pang, S.-Y., Guo, Q., Guan, C., & Jiang, J. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.1c04530 · Cited by 386
Nandy, A., Zhu, J., Janet, J. P., Duan, C., Getman, R. B., & Kulik, H. J. (2019) · ACS Catalysis · doi:10.1021/acscatal.9b02165 · Cited by 91
Metadata
- Authors
- Rohde, J.-U., Torelli, S., Shan, X., Lim, M. H., Klinker, E. J., Kaizer, J., Chen, K., Nam, W., & Que, L.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-12-01
- Volume
- 126
- Issue
- 51
- Pages
- 16750-16761
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2015328651
- Cited by
- 162
- References
- 3
- FWCI
- 9.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.