The DOI matches its Crossref record.
pH-Sensitive Bipolar Ion-Permselective Ultrathin Films
Abstract
pH-Sensitive bipolar ion-permselective films of polyelectrolyte multilayers were prepared by layer-by-layer (LbL) assembly and photo-cross-linking of benzophenone-modified poly(acrylic acid) (PAA-BP) and poly(allylamine hydrochloride) (PAH-BP). The multilayer structure and ionizable group composition was finely tuned by changing the pH of the dipping solution. This structure and composition was in turn "preserved" by photo-cross-linking, forming highly stable membrane films. Since PAA-BP and PAH-BP are weak polyelectrolytes, it is possible to control the number of unbound, un-ionized -COOH or -NH2 groups in the multilayer by changing the pH. Moreover, the pH of the deposited film also plays an important role in determining selective latter permselectivity. For example, PAA-BP/PAH-BP multilayers deposited from two pH conditions, pH = 3 (PAA-BP) and pH = 6 (PAH-BP), showed pH-switchable permselectivity for both cationic (pH = 10) and anionic (pH = 3) probe molecules in a single film. The system offers advantages in film stability and introducing reversible selective ion permeability over previous multilayer film and cross-linking methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ariga, K., Hill, J. P., & Ji, Q. (2007) · Physical Chemistry Chemical Physics · doi:10.1039/b700410a · Cited by 1,256
Layer-by-layer Nanoarchitectonics: Invention, Innovation, and Evolution
Ariga, K., Yamauchi, Y., Rydzek, G., Ji, Q., Yonamine, Y., Wu, K. C.-W., & Hill, J. P. (2014) · Chemistry Letters · doi:10.1246/cl.130987 · Cited by 850
Challenges and breakthroughs in recent research on self-assembly
Ariga, K., Hill, J. P., Lee, M. V., Vinu, A., Charvet, R., & Acharya, S. (2008) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/9/1/014109 · Cited by 759
Multiple Functionalities of Polyelectrolyte Multilayer Films: New Biomedical Applications
Boudou, T., Crouzier, T., Ren, K., Blin, G., & Picart, C. (2010) · Advanced Materials · doi:10.1002/adma.200901327 · Cited by 736
Stimuli-responsive hydrogel thin films
Tokarev, I., & Minko, S. (2009) · Soft Matter · doi:10.1039/b813827c · Cited by 579
Photochemical mechanisms of light-triggered release from nanocarriers
Fomina, N., Sankaranarayanan, J., & Almutairi, A. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.02.006 · Cited by 491
Responsive polymer films and capsules via layer-by-layer assembly
Sukhishvili, S. A. (2005) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2005.05.001 · Cited by 355
Xiang, Y., Lu, S., & Jiang, S. P. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35048c · Cited by 277
Electrochemistry of Multilayer Electrodes: From the Basics to Energy Applications
Gu, M., & Kim, B.-S. (2021) · Accounts of Chemical Research · doi:10.1021/acs.accounts.0c00524 · Cited by 32
Metadata
- Authors
- Park, M.-K., Deng, S., & Advincula, R. C.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-09-30
- Volume
- 126
- Issue
- 42
- Pages
- 13723-13731
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2084439760
- Cited by
- 159
- References
- 0
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.