Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

QZ1 and QZ2: Rapid, Reversible Quinoline-Derivatized Fluoresceins for Sensing Biological Zn(II)

Open access
Nolan, Elizabeth M., Jaworski, Jacek, Okamoto, Ken-Ichi, Hayashi, Yasunori, Sheng, Morgan, Lippard, Stephen J.·2005·Journal of the American Chemical Society

Abstract

QZ1, 2-[2-chloro-6-hydroxy-3-oxo-5-(quinolin-8-ylaminomethyl)-3H-xanthen-9-yl]benzoic acid, and QZ2, 2-[6-hydroxy-3-oxo-4,5-bis-(quinolin-8-ylaminomethyl)-3H-xanthen-9-yl]benzoic acid, two fluorescein-based dyes derivatized with 8-aminoquinoline, have been prepared and their photophysical, thermodynamic, and zinc-binding kinetic properties determined. Because of their low background fluorescence and highly emissive Zn(II) complexes, QZ1 and QZ2 have a large dynamic range, with approximately 42- and approximately 150-fold fluorescence enhancements upon Zn(II) coordination, respectively. These dyes have micromolar K(d) values for Zn(II) and are selective for Zn(II) over biologically relevant concentrations of the alkali and alkaline earth metals. The Zn(II) complexes also fluoresce brightly in the presence of excess Mn(II), Fe(II), Co(II), Cd(II), and Hg(II), offering improved specificity for Zn(II) over di(2-picolyl)amine-based Zn(II) sensors. Stopped-flow kinetic investigations indicate that QZ1 and QZ2 bind Zn(II) with k(on) values of (3-4) x 10(6) M(-1) s(-1), compared to (6-8) x 10(5) M(-1) s(-1) for select ZP (Zinpyr) dyes, at 4.3 degrees C. Dissociation of Zn(II) from QZ1 and QZ2 occurs with k(off) values of 150 and 160 s(-1), over 5 orders of magnitude larger than those for ZP probes, achieving reversibility on the biological (millisecond) time scale. Laser scanning confocal and two-photon microscopy studies reveal that QZ2 is cell-permeable and Zn(II)-responsive in vivo. Because of its weaker affinity for Zn(II), QZ2 responds to higher concentrations of intracellular Zn(II) than members of the ZP family, illustrating that binding affinity is an important parameter for Zn(II) detection in vivo.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja052184t

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 262

Metadata

Authors
Nolan, E. M., Jaworski, J., Okamoto, K.-I., Hayashi, Y., Sheng, M., & Lippard, S. J.
Venue
Journal of the American Chemical Society
Published
2005-11-10
Volume
127
Issue
48
Pages
16812-16823
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W1966380645
Cited by
262
References
1
FWCI
7.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: QZ1 and QZ2: Rapid, Reversible Quinoline-Derivatized Fluoresceins for Sensing Biological Zn(II). https://app.cochat.ai/papers/10.1021/ja052184t
The paper
Nolan, E. M., Jaworski, J., Okamoto, K.-I., Hayashi, Y., Sheng, M., & Lippard, S. J. (2005). QZ1 and QZ2: Rapid, Reversible Quinoline-Derivatized Fluoresceins for Sensing Biological Zn(II). Journal of the American Chemical Society. https://doi.org/10.1021/ja052184t

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.