The DOI matches its Crossref record.
Luminescent Silole Nanoparticles as Chemoselective Sensors for Cr(VI)
Abstract
Colloidal suspensions of 3-aminopropylmethyl(tetraphenyl)silole nanoparticles can be used as selective chemosensors for carcinogenic chromium(VI) analyte. Methylhydrosilole is functionalized by hydrosilation of allylamine, and the colloid is prepared by the rapid addition of water to a THF solution of the silole. The method of detection is through electron-transfer quenching of the fluorescence of the silole colloid (lambda(em) = 485 nm at 360 nm excitation) by the analytes, with hundred parts per billion detection limits. Stern-Volmer plots are linear up to 10 ppm in the case of chromium, but exhibit saturation behavior near 5-10 ppm for arsenic. Dynamic light scattering experiments and AFM measurements show the particle sizes to be around 100 nm in diameter and dependent on solvent composition, with a particle size dispersity of +/-25%. The fluorescence lifetimes of the silole in solution and colloid are approximately 31 ps and approximately 4.3 ns, respectively, while the silole has a lifetime of 6 ns in the bulk solid. A minimum volume fraction of 80% water is necessary to precipitate the colloid from THF, and the luminescence continues to rise with higher water fractions. Colloids in a pH 7 phosphate-buffered suspension show both higher sensitivity and greater selectivity (100-fold) for CrO4(2-) detection than for other oxoanion interferents, NO3-, NO2-, SO4(2-), and ClO4-.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Aggregation‐Induced Emission: The Whole Is More Brilliant than the Parts
Mei, J., Hong, Y., Lam, J. W. Y., Qin, A., Tang, Y., & Tang, B. Z. (2014) · Advanced Materials · doi:10.1002/adma.201401356 · Cited by 3,381
Organophosphorus π-Conjugated Materials
Baumgartner, T., & Réau, R. (2006) · Chemical Reviews · doi:10.1021/cr040179m · Cited by 1,113
Wang, M., Zhang, G., Zhang, D., Zhu, D., & Tang, B. Z. (2010) · Journal of Materials Chemistry · doi:10.1039/b921610c · Cited by 852
Metadata
- Authors
- Toal, S. J., Jones, K. A., Magde, D., & Trogler, W. C.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-07-29
- Volume
- 127
- Issue
- 33
- Pages
- 11661-11665
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2044777503
- Cited by
- 328
- References
- 0
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Luminescent Silole Nanoparticles as Chemoselective Sensors for Cr(VI). https://app.cochat.ai/papers/10.1021/ja052582w
- The paper
- Toal, S. J., Jones, K. A., Magde, D., & Trogler, W. C. (2005). Luminescent Silole Nanoparticles as Chemoselective Sensors for Cr(VI). Journal of the American Chemical Society. https://doi.org/10.1021/ja052582w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.