The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Complementary Detection of Prostate-Specific Antigen Using In2O3 Nanowires and Carbon Nanotubes
Abstract
We report complementary detection of prostate-specific antigen (PSA) using n-type In2O3 nanowires and p-type carbon nanotubes. Our innovation involves developing an approach to covalently attach antibodies to In2O3 NW surfaces via the onsite surface synthesis of phosphonic acid-succinylimide ester. Electronic measurements under dry conditions revealed complementary response for In2O3 NW and SWNT devices after the binding of PSA. Real-time detection in solution has also been demonstrated for PSA down to 5 ng/mL, a benchmark concentration significant for clinical diagnosis of prostate cancer, which is the most frequently diagnosed cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization
Chen, R. J., Zhang, Y., Wang, D., & Dai, H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010172b · Cited by 2,534
Cited by
Carbon nanotubes: properties, synthesis, purification, and medical applications
Eatemadi, A., Daraee, H., Karimkhanloo, H., Kouhi, M., Zarghami, N., Akbarzadeh, A., Abasi, M., Hanifehpour, Y., & Joo, S. W. (2014) · Nanoscale Research Letters · doi:10.1186/1556-276x-9-393 · Cited by 1,239
Highly ordered nanowire arrays on plastic substrates for ultrasensitive flexible chemical sensors
McAlpine, M. C., Ahmad, H., Wang, D., & Heath, J. R. (2007) · Nature Materials · doi:10.1038/nmat1891 · Cited by 959
Electrolyte-Gated Graphene Field-Effect Transistors for Detecting pH and Protein Adsorption
Ohno, Y., Maehashi, K., Yamashiro, Y., & Matsumoto, K. (2009) · Nano Letters · doi:10.1021/nl901596m · Cited by 833
Carbon Nanotube Amplification Strategies for Highly Sensitive Immunodetection of Cancer Biomarkers
Yu, X., Munge, B., Patel, V., Jensen, G., Bhirde, A., Gong, J. D., Kim, S. N., Gillespie, J., Gutkind, J. S., Papadimitrakopoulos, F., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062117e · Cited by 686
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Metadata
- Authors
- Li, C., Curreli, M., Lin, H., Lei, B., Ishikawa, F. N., Datar, R., Cote, R. J., Thompson, M. E., & Zhou, C.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-08-19
- Volume
- 127
- Issue
- 36
- Pages
- 12484-12485
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2324358220
- Cited by
- 378
- References
- 1
- FWCI
- 15.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.