The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A Rhodamine-Based Fluorescent and Colorimetric Chemodosimeter for the Rapid Detection of Hg2+ Ions in Aqueous Media
Abstract
A rhodamine-based fluorescent and colorimetric chemodosimeter for the rapid detection of Hg2+ ions in aqueous media was developed. The system, which utilizes an irreversible Hg2+-promoted oxadiazole forming reaction, responds instantaneously at room temperature in a 1:1 stoichiometric manner to the amount of Hg2+. The selectivity of this system for Hg2+ over other metal ions is remarkably high, and its sensitivity is below 2 ppb in aqueous solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
A Long-Wavelength Fluorescent Chemodosimeter Selective for Cu(II) Ion in Water
Dujols, V., Ford, F., & Czarnik, A. W. (1997) · Journal of the American Chemical Society · doi:10.1021/ja971221g · Cited by 987
Chemical Communication in Water Using Fluorescent Chemosensors
Czarnik, A. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00046a003 · Cited by 943
Ros‐Lis, J. V., Marcos, M. D., Mártinez‐Máñez, R., Rurack, K., & Soto, J. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500583 · Cited by 355
Hwang, K. C., & Mauzerall, D. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00050a086 · Cited by 93
Cited by
Tools and Tactics for the Optical Detection of Mercuric Ion
Nolan, E. M., & Lippard, S. J. (2008) · Chemical Reviews · doi:10.1021/cr068000q · Cited by 2,345
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Self-citationFluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives
Chen, X., Pradhan, T., Wang, F., Kim, J. S., & Yoon, J. (2012) · Chemical Reviews · doi:10.1021/cr200201z · Cited by 1,984
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
A new trend in rhodamine-based chemosensors: application of spirolactam ring-opening to sensing ions
Kim, H. N., Lee, M. H., Kim, H. J., Kim, J. S., & Yoon, J. (2008) · Chemical Society Reviews · doi:10.1039/b802497a · Cited by 1,649
Metadata
- Authors
- Yang, Y.-K., Yook, K.-J., & Tae, J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-11-09
- Volume
- 127
- Issue
- 48
- Pages
- 16760-16761
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1971451316
- Cited by
- 1,044
- References
- 5
- FWCI
- 17.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.