The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Multifunctional Chemical Vapor Sensors of Aligned Carbon Nanotube and Polymer Composites
Abstract
Partially coating perpendicularly aligned carbon nanotube arrays with an appropriate polymer thin film along their tube length provides a novel concept for developing new sensors of high sensitivity, good selectivity, and excellent environmental stability for the detection of a broad class of chemical vapors with low power consumption. The absorption and desorption of chemical vapors by the polymer matrix cause changes in the inter-tube distance and, hence, the surface resistance across the nanotube film. Simple measurements of the resistance change, therefore, constitute the nanotube-polymer chemical vapor sensors. These rationally designed, aligned carbon nanotube-polymer composite films are flexible and can be effectively integrated into many systems for a wide range of potential applications, including their use as multifunctional sensors for sensing chemical vapors, mechanical deformations, thermal and optical exposures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extreme Oxygen Sensitivity of Electronic Properties of Carbon Nanotubes
Collins, P. G., Bradley, K., Ishigami, M., & Zettl, A. (2000) · Science · doi:10.1126/science.287.5459.1801 · Cited by 2,974
Chemical Detection with a Single-Walled Carbon Nanotube Capacitor
Snow, E. S., Perkins, F. K., Houser, E. J., Badescu, S. C., & Reinecke, T. L. (2005) · Science · doi:10.1126/science.1109128 · Cited by 951
Carbon Nanotubes: Science and Applications
Meyyappan, M. (2007) · Medical Entomology and Zoology · Cited by 803
Conducting polyaniline composite: a reusable sensor material for aqueous ammonia
Koul, S., Chandra, R., & Dhawan, S. K. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(00)00685-7 · Cited by 168
Intelligent Macromolecules for Smart Devices: From Materials Synthesis to Device Applications
Dai, L. (2004) · Engineering materials and processes · doi:10.1007/b97517 · Cited by 111
Self-citation
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Carbon nanomaterials for electronics, optoelectronics, photovoltaics, and sensing
Jariwala, D., Sangwan, V. K., Lauhon, L. J., Marks, T. J., & Hersam, M. C. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35335k · Cited by 1,284
Sun, H., Che, R., You, X., Jiang, Y., Yang, Z., Deng, J., Qiu, L., & Peng, H. (2014) · Advanced Materials · doi:10.1002/adma.201403735 · Cited by 1,120
Sensors and actuators based on carbon nanotubes and their composites: A review
Li, C., Thostenson, E. T., & Chou, T.-W. (2008) · Composites Science and Technology · doi:10.1016/j.compscitech.2008.01.006 · Cited by 934
Carbon Nanotube Gas and Vapor Sensors
Kauffman, D. R., & Star, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704488 · Cited by 828
Metadata
- Authors
- Wei, C., Dai, L., Roy, A., & Tolle, T. B.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-01-13
- Volume
- 128
- Issue
- 5
- Pages
- 1412-1413
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1977786515
- Cited by
- 291
- References
- 5
- FWCI
- 24.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.