The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Design and Optimization of Molecular Nanovalves Based on Redox-Switchable Bistable Rotaxanes
Abstract
Redox-controllable molecular nanovalves based on mesoporous silica nanoparticles have been fabricated, using two bistable [2]rotaxanes with different spacer lengths between their recognition sites as the gatekeepers. Three different linkers with varying chain lengths have been employed to attach the bistable [2]rotaxane molecules covalently to the silica substrate. These nanovalves can be classified as having IN or OUT locations, based on the positions of the tethered bistable [2]rotaxanes with respect to the entrances to the nanopores. The nanovalves are more efficient when the bistable [2]rotaxane-based gatekeepers are anchored deep within (IN) the pores than when they are attached closer to (OUT) the pores' orifices. The silica nanopores can be closed and opened by moving the mechanically interlocked ring component of the bistable [2]rotaxane closer to and away from the pores' orifices, respectively, a process which allows luminescent probe molecules, such as coumarins, tris(2-phenylpyridine)iridium, and rhodamine B, to be loaded into or released from the mesoporous silica substrate on demand. The lengths of the linkers between the surface and the rotaxane molecules also play a critical role in determining the effectiveness of the nanovalves. The shorter the linkers, the less leaky are the nanovalves. However, the distance between the recognition units on the rod section of the rotaxane molecules does not have any significant influence on the nanovalves' leakiness. The controlled release of the probe molecules was investigated by measuring their luminescence intensities in response to ascorbic acid, which induces the ring's movement away from the pores' orifices, and consequently opens the nanovalves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minoofar, P. N., Dunn, B. S., & Zink, J. I. (2005) · Journal of the American Chemical Society · doi:10.1021/ja045185e · Cited by 128
Self-citation
Cited by
Mesoporous Silica Nanoparticles for Drug Delivery
Manzano, M., & Vallet‐Regí, M. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201902634 · Cited by 939
Challenges and breakthroughs in recent research on self-assembly
Ariga, K., Hill, J. P., Lee, M. V., Vinu, A., Charvet, R., & Acharya, S. (2008) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/9/1/014109 · Cited by 759
Croissant, J. G., Fatieiev, Y., Almalik, A., & Khashab, N. M. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700831 · Cited by 594
Light‐Activated Nanoimpeller‐Controlled Drug Release in Cancer Cells
Lu, J., Choi, E., Tamanoi, F., & Zink, J. I. (2008) · Small · doi:10.1002/smll.200700903 · Cited by 462
Self-citationTunable Redox-Responsive Hybrid Nanogated Ensembles
Liu, R., Zhao, X., Wu, T., & Feng, P. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8060886 · Cited by 391
Metadata
- Authors
- Nguyen, T. D., Liu, Y., Saha, S., Leung, K. C.-F., Stoddart, J. F., & Zink, J. I.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-01-01
- Volume
- 129
- Issue
- 3
- Pages
- 626-634
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1976893205
- Cited by
- 397
- References
- 1
- FWCI
- 24.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Optimization of Molecular Nanovalves Based on Redox-Switchable Bistable Rotaxanes. https://app.cochat.ai/papers/10.1021/ja065485r
- The paper
- Nguyen, T. D., Liu, Y., Saha, S., Leung, K. C.-F., Stoddart, J. F., & Zink, J. I. (2007). Design and Optimization of Molecular Nanovalves Based on Redox-Switchable Bistable Rotaxanes. Journal of the American Chemical Society. https://doi.org/10.1021/ja065485r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.