The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Interfacing Silicon Nanowires with Mammalian Cells
Abstract
We present the first demonstration of a direct interface of silicon nanowires with mammalian cells such as mouse embryonic stem (mES) cells and human embryonic kidney (HEK 293T) cells without any external force. The cells were cultured on a silicon (Si) substrate with a vertically aligned SiNW array on it. The penetration of the SiNW array into individual cells naturally occurred during the incubation. The cells survived up to several days on the nanowire substrates. The longevity of the cells was highly dependent on the diameter of SiNWs. Furthermore, successful maintenance of cardiac myocytes derived from mES cells on the wire array substrates was observed, and gene delivery using the SiNW array was demonstrated. Our results suggest that the nanowires can be potentially utilized as a powerful tool for studying intra- and intercellular biological processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semiconductor Clusters, Nanocrystals, and Quantum Dots
Alivisatos, A. P. (1996) · Science · doi:10.1126/science.271.5251.933 · Cited by 11,528
Nanoshell-mediated near-infrared thermal therapy of tumors under magnetic resonance guidance
Hirsch, L. R., Stafford, R. J., Bankson, J. A., Sershen, S. R., Rivera, B., Price, R. E., Hazle, J. D., Halas, N. J., & West, J. L. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2232479100 · Cited by 3,955
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Silicon Vertically Integrated Nanowire Field Effect Transistors
Goldberger, J., Hochbaum, A. I., Fan, R., & Yang, P. (2006) · Nano Letters · doi:10.1021/nl060166j · Cited by 776
Self-citationControlled Growth of Si Nanowire Arrays for Device Integration
Hochbaum, A. I., Fan, R., He, R., & Yang, P. (2005) · Nano Letters · doi:10.1021/nl047990x · Cited by 657
Self-citationMagnetic Clusters in Molecular Beams, Metals, and Semiconductors
Shi, J., Gider, S., Babcock, K., & Awschalom, D. D. (1996) · Science · doi:10.1126/science.271.5251.937 · Cited by 465
Mouse embryonic stem cells express the cardiac myosin heavy chain genes during development in vitro.
Robbins, J., Gulick, J., Sanchez, A., Howles, P., & Doetschman, T. (1990) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)38485-6 · Cited by 173
Cited by
Bactericidal activity of black silicon
Ivanova, E. P., Hasan, J., Webb, H. K., Gervinskas, G., Juodkazis, S., Truong, V. K., Wu, A. H. F., Lamb, R. N., Baulin, V. A., Watson, G. S., et al. (2013) · Nature Communications · doi:10.1038/ncomms3838 · Cited by 973
25th Anniversary Article: Semiconductor Nanowires – Synthesis, Characterization, and Applications
Dasgupta, N. P., Sun, J., Liu, C., Brittman, S., Andrews, S. C., Lim, J., Gao, H., Yan, R., & Yang, P. (2014) · Advanced Materials · doi:10.1002/adma.201305929 · Cited by 880
Self-citationSemiconductor Nanowire: What’s Next?
Yang, P., Yan, R., & Fardy, M. (2010) · Nano Letters · doi:10.1021/nl100665r · Cited by 787
Self-citationIntracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Metadata
- Authors
- Kim, W., Ng, J. K., Kunitake, M. E., Conklin, B. R., & Yang, P.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-05-22
- Volume
- 129
- Issue
- 23
- Pages
- 7228-7229
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1982716000
- Cited by
- 528
- References
- 8
- FWCI
- 17.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.