The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Highly Selective Fluorescence Turn-on Sensor for Cysteine/Homocysteine and Its Application in Bioimaging
Abstract
We demonstrated a highly electron-deficient system 1 as a turn-on fluorescence sensor for intracellular imaging of Cys/Hcy in biological samples. On the basis of the specific nucleophilic ability of thiols of Cys and Hcy, 1 exhibited high selectivity and sensitivity for Cys/Hcy over other amino acids and thiol biomolecules. This probe is the first Cys/Hcy sensor with excitation in the visible region and turn-on (75-fold) fluorescence emission and also gives a significant increase in two-photon excited fluorescence for sensing Cys/Hcy. Moreover, confocal laser scanning microscopy and two-photon laser scanning microscopy experiments further established that 1 can be used for sensing Cys/Hcy within biological samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Homocysteine and Cardiovascular Disease
Refsum, H., Ueland, P. M., Nygård, O., & Vollset, S. E. (1998) · Annual Review of Medicine · doi:10.1146/annurev.med.49.1.31 · Cited by 2,180
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Small-Molecule Two-Photon Probes for Bioimaging Applications
Kim, H. M., & Cho, B. R. (2015) · Chemical Reviews · doi:10.1021/cr5004425 · Cited by 1,047
Yang, X., Guo, Y., & Strongin, R. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201103759 · Cited by 658
Ratiometric Detection of Mitochondrial Thiols with a Two-Photon Fluorescent Probe
Lim, C. S., Masanta, G., Kim, H. J., Han, J. H., Kim, H. M., & Cho, B. R. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205081s · Cited by 365
Metadata
- Authors
- Zhang, M., Yu, M., Li, F., Zhu, M., Li, M., Gao, Y., Li, L., Liu, Z., Zhang, J., Zhang, D., Yi, T., & Huang, C.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-08-01
- Volume
- 129
- Issue
- 34
- Pages
- 10322-10323
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1971341023
- Cited by
- 502
- References
- 2
- FWCI
- 16.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.