The DOI matches its Crossref record.
Self-delivering Nanoemulsions for Dual Fluorine-19 MRI and Fluorescence Detection
Abstract
We report the design, synthesis, and biological testing of highly stable, nontoxic perfluoropolyether (PFPE) nanoemulsions for dual 19F MRI-fluorescence detection. A linear PFPE polymer was covalently conjugated to common fluorescent dyes (FITC, Alexa647 and BODIPy-TR), mixed with pluronic F68 and linear polyethyleneimine (PEI), and emulsified by microfluidization. Prepared nanoemulsions (<200 nm) were readily taken up by both phagocytic and non-phagocytic cells in vitro after a short (approximately 3 h) co-incubation. Following cell administration in vivo, 19F MRI selectively visualizes cell migration. Exemplary in vivo MRI images are presented of T cells labeled with a dual-mode nanoemulsion in a BALB/c mouse. Fluorescence detection enables fluorescent microscopy and FACS analysis of labeled cells, as demonstrated in several immune cell types including Jurkat cells, primary T cells and dendritic cells. The intracellular fluorescence signal is directly proportional to the 19F NMR signal and can be used to calibrate cell loading in vitro.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multimodality Imaging Probes: Design and Challenges
Louie, A. (2010) · Chemical Reviews · doi:10.1021/cr9003538 · Cited by 1,044
Compound Copper Chalcogenide Nanocrystals
Coughlan, C., Ibáñez, M., Dobrozhan, O., Singh, A., Cabot, A., & Ryan, K. M. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00376 · Cited by 930
Zhao, Z., Fan, H., Zhou, G., Bai, H., Liang, H., Wang, R., Zhang, X., & Tan, W. (2014) · Journal of the American Chemical Society · doi:10.1021/ja5029364 · Cited by 584
19F Magnetic Resonance Imaging (MRI): From Design of Materials to Clinical Applications
Tirotta, I., Dichiarante, V., Pigliacelli, C., Cavallo, G., Terraneo, G., Bombelli, F. B., Metrangolo, P., & Resnati, G. (2015) · Chemical Reviews · doi:10.1021/cr500286d · Cited by 521
Zhang, C., Yan, K., Fu, C., Peng, H., Hawker, C. J., & Whittaker, A. K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00632 · Cited by 493
Fluorine (19F) MRS and MRI in biomedicine
Ruiz‐Cabello, J., Barnett, B. P., Bottomley, P. A., & Bulte, J. W. M. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1570 · Cited by 489
Fluoropolymers in Biomedical Applications: State-of-the-Art and Future Perspectives
Lv, J., & Cheng, Y. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00258e · Cited by 316
Metadata
- Authors
- Janjic, J. M., Srinivas, M., Kadayakkara, D. K. K., & Ahrens, E. T.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-02-12
- Volume
- 130
- Issue
- 9
- Pages
- 2832-2841
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2127215370
- Cited by
- 260
- References
- 0
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.