The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Kinetics of Redox Polymer-Mediated Enzyme Electrodes
Abstract
Oxygen-reducing enzyme electrodes are prepared from laccase of Trametes versicolor and a series of osmium-based redox polymer mediators covering a range of redox potentials from 0.11 to 0.85 V. Experimentally obtained current density generated by the film electrodes is analyzed using a one-dimensional numerical model to obtain kinetic parameters. The bimolecular rate constant for mediation is found to vary with mediator redox potential from 250 s(-1) M(-1) when mediator and enzyme are close in redox potential to 9.4 x 10(4) s(-1) M(-1) when the redox potential difference is large. The value of the bimolecular rate constant for the simultaneously occurring laccase-oxygen reaction is found to be 2.4 x 10(5) s(-1) M(-1). The relationship between mediator-enzyme overpotential and bimolecular rate constant is used to determine the optimum mediator redox potential for maximum power output of a hypothetical biofuel cell with a planar cathode and a reversible hydrogen anode. For laccase of T. versicolor (E(e)(0) = 0.82), the optimum mediator potential is 0.66 V (SHE), and a molecular structure is presented to achieve this result.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multicopper oxidases and oxygenases
Solomon, E. I., Sundaram, U. M., & Machonkin, T. E. (1996) · Chemical Reviews · doi:10.1021/cr950046o · Cited by 3,664
Cited by
A review on non-precious metal electrocatalysts for PEM fuel cells
Chen, Z., Higgins, D., Yu, A., Zhang, L., & Zhang, J. (2011) · Energy & Environmental Science · doi:10.1039/c0ee00558d · Cited by 1,832
Electroreduction of Dioxygen for Fuel-Cell Applications: Materials and Challenges
Gewirth, A. A., & Thorum, M. S. (2010) · Inorganic Chemistry · doi:10.1021/ic9022486 · Cited by 705
The ins and outs of microorganism–electrode electron transfer reactions
Kumar, A., Hsu, L. H.-H., Kavanagh, P., Barrière, F., Lens, P. N. L., Lapinsonnière, L., Lienhard V, J. H., Schröder, U., Jiang, X., & Leech, D. (2017) · Nature Reviews Chemistry · doi:10.1038/s41570-017-0024 · Cited by 541
Enzymatic biofuel cells: 30 years of critical advancements
Rasmussen, M., Abdellaoui, S., & Minteer, S. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.029 · Cited by 483
Enzymatic fuel cells: Recent progress
Leech, D., Kavanagh, P., & Schuhmann, W. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.02.087 · Cited by 446
Metadata
- Authors
- Gallaway, J. W., & Calabrese Barton, S. A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-06-07
- Volume
- 130
- Issue
- 26
- Pages
- 8527-8536
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2027095729
- Cited by
- 179
- References
- 1
- FWCI
- 14.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.