The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Simultaneous Noncontact Topography and Electrochemical Imaging by SECM/SICM Featuring Ion Current Feedback Regulation
Abstract
We described a hybrid system of scanning electrochemical microscopy (SECM) and scanning ion conductance microscopy (SICM) with ion current feedback nanopositioning control for simultaneous imaging of noncontact topography and spatial distribution of electrochemical species. A nanopipette/nanoring electrode probe provided submicrometer resolution of the electrochemical measurement on surfaces with complex topology. The SECM/SICM probe had an aperture radius of 220 nm. The inner and outer radii of the SECM Au nanoring electrode were 330 and 550 nm, respectively. Characterization of the probe was performed with scanning electron microscopy (SEM), cyclic voltammetry (CV), and approach curve measurements. SECM/SICM was applied to simultaneous imaging of topography and electrochemical responses of enzymes (horse radish peroxidase (HRP) and glucose oxidase (GOD)) and single live cells (A6 cells, superior cervical ganglion (SCG) cells, and cardiac myocytes). The measurements revealed the distribution of activity of the enzyme spots on uneven surfaces with submicrometer resolution. SECM/SICM acquired high resolution topographic images of cells together with the map of electrochemical signals. This combined technique was also applied to the evaluation of the permeation property of electroactive species through cellular membranes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lyon, A. R., MacLeod, K. T., Zhang, Y., Garcia, E., Kanda, G. K., Lab, M. J., Korchev, Y. E., Harding, S. E., & Gorelik, J. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0809777106 · Cited by 369
Self-citationNanoelectrochemistry of mammalian cells
Sun, P., Laforge, F. O., Abeyweera, T. P., Rotenberg, S. A., Carpino, J., & Mirkin, M. V. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711075105 · Cited by 213
Liu, B., Rotenberg, S. A., & Mirkin, M. V. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.18.9855 · Cited by 192
Dynamic assembly of surface structures in living cells
Gorelik, J., Shevchuk, A. I., Frolenkov, G. I., Diakonov, I. A., Lab, M. J., Kros, C. J., Richardson, G. P., Vodyanoy, I., Edwards, C. R. W., Klenerman, D., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1030502100 · Cited by 176
Self-citationComstock, D. J., Elam, J. W., Pellin, M. J., & Hersam, M. C. (2010) · Analytical Chemistry · doi:10.1021/ac902224q · Cited by 169
Scanning Electrochemical Microscopy of Model Neurons: Constant Distance Imaging
Kurulugama, R. T., Wipf, D. O., Takacs, S. A., Pongmayteegul, S., Garris, P. A., & Baur, J. E. (2005) · Analytical Chemistry · doi:10.1021/ac048571n · Cited by 151
Gorelik, J., Gu, Y., Spohr, H. A., Shevchuk, A., Lab, M. J., Harding, S. E., Edwards, C. R. W., Whitaker, M., Moss, G. W. J., Benton, D. C. H., et al. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75330-7 · Cited by 119
Self-citationScanning Electrochemical Microscopy of Living Cells. 3. Rhodobacter sphaeroides
Cai, C., Liu, B., Mirkin, M. V., Frank, H. A., & Rusling, J. F. (2001) · Analytical Chemistry · doi:10.1021/ac010945e · Cited by 110
Scanning electrochemical microscopy of living cells
Liu, B., Cheng, W., Rotenberg, S. A., et al. (2001) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(00)00436-8 · Cited by 103
Gorelik, J., Shevchuk, A., Ramalho, M., Elliott, M., Lei, C., Higgins, C. F., Lab, M. J., Klenerman, D., Krauzewicz, N., & Korchev, Y. E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.252458399 · Cited by 103
Self-citation
Cited by
Ebejer, N., Güell, A. G., Lai, S. C. S., McKelvey, K., Snowden, M. E., & Unwin, P. R. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092650 · Cited by 355
Kuzuya, A., Nomura, S.-I. M., Toyota, T., Nakakuki, T., & Murata, S. (2023) · IEEE Transactions on Molecular, Biological and Multi-Scale Communications · doi:10.1109/tmbmc.2023.3304243 · Cited by 29
Metadata
- Authors
- Takahashi, Y., Shevchuk, A. I., Novak, P., Murakami, Y., Shiku, H., Korchev, Y. E., & Matsue, T.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-06-30
- Volume
- 132
- Issue
- 29
- Pages
- 10118-10126
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1969357101
- Cited by
- 297
- References
- 13
- FWCI
- 13.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.