Understanding Zinc Quantification with Existing and Advanced Ditopic Fluorescent Zinpyr Sensors
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Treatment of aqueous zinc solutions with incremental additions of a ditopic fluorescent sensor of the Zinpyr family, based on pyridine/pyrazine-containing metal recognition units, affords a fluorescence titration curve with a sharp maximum at a sensor:Zn(2+) ratio of 0.5 (Zhang, X-a.; Hayes, D.; Smith, S. J.; Friedle, S.; Lippard, S. J. J. Am. Chem. Soc.2008, 130, 15788-15789). This fluorescence response enables the quantification of readily chelatable zinc in biological samples by a simple titration protocol. In the present work a new set of ditopic fluorescence zinc sensors functionalized with pyridine/pyrazine-containing metal chelating units is described, and through detailed studies the principles governing the characteristic OFF-ON-OFF fluorescence behavior and quantification capabilities of the family are delineated. Incorporation of carboxylate/ester groups in the 6 position of the fluorescein allows for control of the spatial distribution of the sensor for selective extra- or intracellular imaging of mobile zinc, without introducing significant changes in zinc-binding properties. A combination of spectrophotometric and potentiometric measurements provided a complete description of the H(+)- and Zn(2+)-binding properties of the compounds and their correlation with the observed fluorescence profile. The first zinc-binding event has an apparent affinity, K(1)', of 1.9 × 10(9)-3.1 × 10(9) M(-1), whereas for coordination of the second Zn(2+) ion, responsible for fluorescence turn-on, the apparent formation constant, K(2)', is 5.5 × 10(7)-6.9 × 10(7) M(-1). A detailed chemical and mathematical analysis of the system demonstrated that the difference in emission efficiencies of the dimetalated (LZn(2)) vs monometalated (LZn) and metal-free (L) forms, a consequence of the combined quenching effects of the two metal-chelating units, significantly influences the shape of the titration curve. The scope of the titration method was investigated mathematically, and a lower boundary for the range of concentrations that can be determined was established as a function of the magnitude of K(2)'. Our results suggest that the principles governing the response of the ZPP1 series are applicable to other analogues of the Zinpyr family. Moreover, they may guide the design of other ditopic sensors suitable for determining the concentrations of a wide range of mobile metal ions and other chemical signaling agents of relevance in biological systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Fulmer, G. R., Miller, A. J. M., Sherden, N. H., Gottlieb, H. E., Nudelman, A., Stoltz, B. M., Bercaw, J. E., & Goldberg, K. I. (2010) · Organometallics · doi:10.1021/om100106e · Cited by 4,050
GANS, P., SABATINI, A., & VACCA, A. (1996) · Talanta · doi:10.1016/0039-9140(96)01958-3 · Cited by 3,264
The biochemical basis of zinc physiology
Vallee, B. L., & Falchuk, K. H. (1993) · Physiological Reviews · doi:10.1152/physrev.1993.73.1.79 · Cited by 2,990
Thomas, J. A., Buchsbaum, R. N., Zimniak, A., & Racker, E. (1979) · Biochemistry · doi:10.1021/bi00578a012 · Cited by 2,132
Metals in Neurobiology: Probing Their Chemistry and Biology with Molecular Imaging
Que, E. L., Domaille, D. W., & Chang, C. J. (2008) · Chemical Reviews · doi:10.1021/cr078203u · Cited by 2,061
The neurobiology of zinc in health and disease
Frederickson, C. J., Koh, J.-Y., & Bush, A. I. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1671 · Cited by 1,850
Binding constants: The measurement of molecular complex stability
(1987) · European Journal of Medicinal Chemistry · doi:10.1016/0223-5234(87)90280-7 · Cited by 1,779
Alderighi, L., Gans, P., Ienco, A., Peters, D., Sabatini, A., & Vacca, A. (1999) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(98)00260-4 · Cited by 1,668
A non-disruptive technique for loading calcium buffers and indicators into cells
Tsien, R. Y. (1981) · Nature · doi:10.1038/290527a0 · Cited by 1,131
Cited by
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Fluorescent probes for the selective detection of chemical species inside mitochondria
Xu, Z., & Xu, L. (2016) · Chemical Communications · doi:10.1039/c5cc09248e · Cited by 291
Yang, Z., Loh, K. Y., Chu, Y.-T., Feng, R., Satyavolu, N. S. R., Xiong, M., Nakamata Huynh, S. M., Hwang, K., Li, L., Xing, H., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b09867 · Cited by 252
Metadata
- Authors
- Buccella, D., Horowitz, J. A., & Lippard, S. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-02-25
- Volume
- 133
- Issue
- 11
- Pages
- 4101-4114
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2052682096
- Cited by
- 161
- References
- 41
- FWCI
- 11.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.