The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Self-Regulating Enzyme−Nanotube Ensemble Films and Their Application as Flexible Electrodes for Biofuel Cells
Abstract
Nanostructured carbons have been widely used for fabricating enzyme-modified electrodes due to their large specific surface area. However, because they are random aggregates of particular or tubular nanocarbons, the postmodification of enzymes to their intrananospace is generally hard to control. Here, we describe a free-standing film of carbon nanotube forest (CNTF) that can form a hybrid ensemble with enzymes through liquid-induced shrinkage. This provides in situ regulation of its intrananospace (inter-CNT pitch) to the size of enzymes and eventually serves as a highly active electrode. The CNTF ensemble with fructose dehydrogenase (FDH) showed the oxidation current density of 16 mA cm(-2) in stirred 200 mM fructose solution. The power density of a biofuel cell using the FDH-CNTF anode and the Laccase-CNTF cathode reached 1.8 mW cm(-2) (at 0.45 V) in the stirred oxygenic fructose solution, more than 80% of which could be maintained after continuous operation for 24 h. Application of the free-standing, flexible character of the enzyme-CNTF ensemble electrodes is demonstrated via their use in the patch or wound form.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Piontek, K., Antorini, M., & Choinowski, T. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m204571200 · Cited by 909
Cited by
Enzymatic biofuel cells: 30 years of critical advancements
Rasmussen, M., Abdellaoui, S., & Minteer, S. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.029 · Cited by 483
O2Reduction in Enzymatic Biofuel Cells
Mano, N., & de Poulpiquet, A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00220 · Cited by 337
Nanostructured material-based biofuel cells: recent advances and future prospects
Zhao, C.-E., Gai, P., Song, R., Chen, Y., Zhang, J., & Zhu, J.-J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00044d · Cited by 324
Stretchable biofuel cell with enzyme-modified conductive textiles
Ogawa, Y., Takai, Y., Kato, Y., Kai, H., Miyake, T., & Nishizawa, M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.063 · Cited by 76
Self-citation
Metadata
- Authors
- Miyake, T., Yoshino, S., Yamada, T., Hata, K., & Nishizawa, M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-03-10
- Volume
- 133
- Issue
- 13
- Pages
- 5129-5134
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2090397081
- Cited by
- 223
- References
- 2
- FWCI
- 19.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-Regulating Enzyme−Nanotube Ensemble Films and Their Application as Flexible Electrodes for Biofuel Cells. https://app.cochat.ai/papers/10.1021/ja111517e
- The paper
- Miyake, T., Yoshino, S., Yamada, T., Hata, K., & Nishizawa, M. (2011). Self-Regulating Enzyme−Nanotube Ensemble Films and Their Application as Flexible Electrodes for Biofuel Cells. Journal of the American Chemical Society. https://doi.org/10.1021/ja111517e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.