Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 239

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

In Situ Preparation of Highly Fluorescent Dyes upon Photoirradiation

Uno, Kakishi, Niikura, Hiroyuki, Morimoto, Masakazu, Ishibashi, Yukihide, Miyasaka, Hiroshi, Irie, Masahiro·2011·Journal of the American Chemical Society

Abstract

Photoswitchable or photoactivatable fluorescent dyes are potentially applicable to ultrahigh density optical memory media as well as super-resolution fluorescence imaging when the dyes are highly fluorescent and have large absorption coefficients. Here, we report on highly fluorescent photochromic dyes, which are initially nonluminous in solution under irradiation with visible light but activated to emit green or red fluorescence upon irradiation with ultraviolet (UV) light. The dyes 5a-9a are sulfone derivatives of 1,2-bis(2-ethyl-6-phenyl(or thienyl)-1-benzothiophen-3-yl)perfluorocyclopentene. It was found that substitution of phenyl or thiophene rings at 6 and 6' positions of the benzothiophene-1,1-dioxide groups is effective to increase the fluorescence quantum yields of the closed-ring isomers over 0.7 and absorption coefficients over 4 × 10(4) M(-1) cm(-1). The phenyl-substituted derivatives 5a-7a undergo photocyclization reactions to produce yellow closed-ring isomers 5b-7b, which emit brilliant green fluorescence at around 550 nm (Φ(F) = 0.87-0.88) under irradiation with 488 nm light. Any absorption intensity change of the closed-ring isomers was not observed even after 100 h storage in the dark at 80 °C. The closed-ring isomers slowly returned to the initial open-ring isomers upon irradiation with visible (λ > 480 nm) light. The ring-opening quantum yields (Φ(C→O)) were measured to be (1.6-4.0) × 10(-4). When the phenyl substituents are replaced with thiophene rings, such as compounds 8a and 9a, the absorption bands of the closed-ring isomers shift to longer than 500 nm. The closed-ring isomers exhibit brilliant red fluorescences at around 620 nm (Φ(F) = 0.61-0.78) under irradiation with 532 nm light. The ring-opening reactions are very slow (Φ(C→O) < 1 × 10(-5)). The fluorescence lifetimes of these sulfone derivatives were measured to be around 2-3 ns, which is much longer than the value of the closed-ring isomer of 1,2-bis(2-methyl-1-benzothiophen-3-yl)perfluorocyclopentene (τ(F) = 4 and 22 ps). The closed-ring isomer 8b in 1,4-dioxane exhibits excellent fatigue resistant property under irradiation with visible light (λ > 440 nm) superior to the stability of Rhodamine 101 in ethanol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja204583e

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 239

Metadata

Authors
Uno, K., Niikura, H., Morimoto, M., Ishibashi, Y., Miyasaka, H., & Irie, M.
Venue
Journal of the American Chemical Society
Published
2011-08-05
Volume
133
Issue
34
Pages
13558-13564
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2320811399
Cited by
239
References
1
FWCI
7.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.