The DOI matches its Crossref record.
Attogram Sensing of Trinitrotoluene with a Self-Assembled Molecular Gelator
Abstract
Detection of explosives is of utmost importance due to the threat to human security as a result of illegal transport and terrorist activities. Trinitrotoluene (TNT) is a widely used explosive in landmines and military operations that contaminates the environment and groundwater, posing a threat to human health. Achieving the detection of explosives at a sub-femtogram level using a molecular sensor is a challenge. Herein we demonstrate that a fluorescent organogelator exhibits superior detection capability for TNT in the gel form when compared to that in the solution state. The gel when coated on disposable paper strips detects TNT at a record attogram (ag, 10(-18) g) level (∼12 ag/cm(2)) with a detection limit of 0.23 ppq. This is a simple and low-cost method for the detection of TNT on surfaces or in aqueous solutions in a contact mode, taking advantage of the unique molecular packing of an organogelator and the associated photophysical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Okesola, B. O., & Smith, D. K. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00124f · Cited by 760
Joarder, B., Desai, A. V., Samanta, P., Mukherjee, S., & Ghosh, S. K. (2015) · Chemistry – A European Journal · doi:10.1002/chem.201405167 · Cited by 334
Highly Selective and Sensitive Fluorescent Paper Sensor for Nitroaromatic Explosive Detection
Ma, Y., Li, H., Peng, S., & Wang, L. (2012) · Analytical Chemistry · doi:10.1021/ac302138c · Cited by 283
Metadata
- Authors
- Kartha, K. K., Babu, S. S., Srinivasan, S., & Ajayaghosh, A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-05
- Volume
- 134
- Issue
- 10
- Pages
- 4834-4841
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2008556668
- Cited by
- 486
- References
- 0
- FWCI
- 25.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.