The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantitation of Femtomolar Protein Levels via Direct Readout with the Electrochemical Proximity Assay
Open accessAbstract
We have developed a separation-free, electrochemical assay format with direct readout that is amenable to highly sensitive and selective quantitation of a wide variety of target proteins. Our first generation of the electrochemical proximity assay (ECPA) is composed of two thrombin aptamers which form a cooperative complex only in the presence of target molecules, moving a methylene blue (MB)-conjugated oligonucleotide close to a gold electrode. Without washing steps, electrical current is increased in proportion to the concentration of a specific target protein. By employing a DNA-based experimental model with the aptamer system, we show that addition of a short DNA competitor can reduce background current of the MB peak to baseline levels. As such, the detection limit of aptamer-based ECPA for human thrombin was 50 pM via direct readout. The dual-probe nature of ECPA gave high selectivity and 93% recovery of signal from 2.5 nM thrombin in 2% bovine serum albumin (BSA). To greatly improve the flexibility of ECPA, we then proved the system functional with antibody-oligonucleotide conjugates as probes; the insulin detection limit was 128 fM with a dynamic range of over 4 orders of magnitude in concentration, again with high assay selectivity. ECPA thus allows separation-free, highly sensitive, and highly selective protein detection with a direct electrochemical readout. This method is extremely flexible, capable of detecting a wide variety of protein targets, and is amenable to point-of-care protein measurement, since any target with two aptamers or antibodies could be assayed via direct electrochemical readout.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
The Aptamer Handbook: Functional Oligonucleotides and Their Applications
(2006) · doi:10.1002/3527608192 · Cited by 220
Cited by
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Aptamer binding assays for proteins: The thrombin example—A review
Deng, B., Lin, Y., Wang, C., Li, F., Wang, Z., Zhang, H., Li, X.-F., & Le, X. C. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.04.055 · Cited by 379
Nanotechnology-Enhanced No-Wash Biosensors for in Vitro Diagnostics of Cancer
Huang, X., Liu, Y., Yung, B., Xiong, Y., & Chen, X. (2017) · ACS Nano · doi:10.1021/acsnano.7b02618 · Cited by 259
Metadata
- Authors
- Hu, J., Wang, T., Kim, J., Shannon, C., & Easley, C. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-10
- Volume
- 134
- Issue
- 16
- Pages
- 7066-7072
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2328559027
- Cited by
- 167
- References
- 2
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitation of Femtomolar Protein Levels via Direct Readout with the Electrochemical Proximity Assay. https://app.cochat.ai/papers/10.1021/ja3000485
- The paper
- Hu, J., Wang, T., Kim, J., Shannon, C., & Easley, C. J. (2012). Quantitation of Femtomolar Protein Levels via Direct Readout with the Electrochemical Proximity Assay. Journal of the American Chemical Society. https://doi.org/10.1021/ja3000485
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.